Section 12 – J7 Trigger Outputs
12-7
Wiring Auxiliary Alarm Signaling Equipment
Refer to Figures 12-5a and b to make connections to the 7720, 7920SE and 7720ULF Long
Range Radios.
GND (GRAY)
BURG/AUDIBLE PANIC (BROWN) REQUIRED
SILENT PANIC/DURESS (BLACK) OPTIONAL
FIRE (RED) OPTIONAL
7720 RADIO
FAULT
FAULT
ZONE 1
ZONE 2
ZONE 3
ZONE 4
GND
SEE 7720 INST. INSTR. FOR
INSTRUCTIONS ON POWERING UNIT
12345678910
12345678
}
28 29 30
J7
4142TR CABLE
659EN LINE FAULT MONITOR
FAULT
+12V GND
ORANGE
YELLOW
GREEN
PHONE LINE MONITOR
(+12V ON FAULT)
OPTIONAL
SEE
NOTE 4
INCOMING PHONE LINE
PHONE LINE MONITOR
(OPENS ON FAULT)
REQUIRED
7 BLACK
6 RED
TO C-COM
AUX PWR
(35mA DRAW)
EARTH GROUND
RING
TIP
CONTROL
PANEL
7720 WIRING
NOTES:
FOR UL LISTED COMMERCIAL BURGLARY
INSTALLATIONS:
1. MOUNT THE 7720 WITHIN 3 FEET OF THE
C-COM. RUN WIRING FROM C-COM TO 7720
IN CONDUIT.
2. CONNECT RADIO FAULT OUTPUT TO C-COM
EOLR SUPERVISED ZONE (ZONE 2-8 ONLY).
USE 2K EOLR.
3. SEE UL INSTALLATION REQUIREMENTS ON A
LATER PAGE TO DETERMINE WHEN 659EN
USAGE IS REQUIRED.
4. CONNECT TO C-COM EOLR SUPERVISED
ZONE (ZONE 2-8 ONLY) WHEN DESIRED TO
HAVE PANEL LOCALLY ANNUNCIATE PHONE
LINE FAULTS.
7920SE RADIO
FAULT
ZONE 6
ZONE 3
ZONE 2
ZONE 1
EARTH GROUND
CABINET GROUND
SEE 7920SE INST. INSTR. FOR
INSTRUCTIONS ON POWERING UNIT
12345678910
12345678910
TB1
TB2
12345678
GND (GRAY)
FIRE (RED) OPTIONAL
SILENT PANIC/DURESS (BLACK) OPTIONAL
BURG/AUDIBLE PANIC (BROWN) REQUIRED
28 29 30
J7
CONNECT
TO C-COM
EARTH GROUND
SCREW (TB30)
4142TR CABLE
SEE NOTE 2
4.7K (NOT SUPPLIED)
RADIO OK OUTPUT
(LOW ON FAULT)
659EN LINE FAULT MONITOR
FAULT
+12V GND
ORANGE
YELLOW
GREEN
PHONE LINE MONITOR
(+12V ON FAULT)
OPTIONAL
SEE
NOTE 4
INCOMING PHONE LINE
PHONE LINE MONITOR
(OPENS ON FAULT)
REQUIRED
7 BLACK
6 RED
7920SE WIRING
NOTES:
FOR UL LISTED COMMERCIAL BURGLARY
INSTALLATIONS:
1. MOUNT THE 7920SE WITHIN 3 FEET OF THE
C-COM. RUN WIRING FROM C-COM TO
7920SE IN CONDUIT.
2. CONNECT RADIO OK OUTPUT TO C-COM
EOLR SUPERVISED ZONE (ZONE 2-7 ONLY).
USE 2K EOLR.
3. SEE UL INSTALLATION REQUIREMENTS ON A
LATER PAGE TO DETERMINE WHEN 659EN
USAGE IS REQUIRED.
4. CONNECT TO C-COM EOLR SUPERVISED
ZONE (ZONE 2-8 ONLY) WHEN DESIRED TO
HAVE PANEL LOCALLY ANNUNCIATE PHONE
LINE FAULTS.
SEE NOTE 2
RADIO FAULT OUTPUT
(PROGRAM FOR SHORT ON FAULT)
FAULT
TO C-COM
AUX PWR
(35mA DRAW)
EARTH GROUND
RING
TIP
}
}
}
CONTROL
PANEL
Figure 12-5a. Connections to 7720 & 7920SELong Range Radios