VISTA-128B Installation Instructions
24-12
Arm/Disarm Commands
Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for automatic
arming and disarming functions.
"During" can be used to arm or disarm the control for a specific time only. For example, if
"during" is selected with Arm-STAY, the system will automatically Arm-STAY at the
beginning of the window and automatically disarm at the end of the window.
Action Code Action Specifier
20 Arm-STAY Partition(s)
21 Arm AWAY Partition(s)
22 Disarm Partition(s)
23 Force Arm STAY (Auto-bypass faulted zns) Partition(s)
24 Force Arm AWAY (Auto-bypass faulted zns) Partition(s)
1.
The auto-arm warning (field 2*06) applies when using time-driven events to auto-arm.
2.
Temporary schedules will not override an auto-arming or auto-disarming programmed in time-
driven events.
3.
The auto-arming window cannot be extended using the Installer Code + #82 Mode.
Bypass Commands
Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for bypass
commands. If 3 (During) is selected for auto-bypassing, the system will bypass the zone(s)
specified on a particular zone list at the beginning of the window and unbypass the zone(s)
at the end of the window. If it is selected for auto unbypassing, the system will remove
the bypass of the zone(s) at the beginning of the window and will restore the bypass of the
zone(s) at the end of the window.
Action Code Action Specifier
30 Auto bypass - Zone list Zone list #
31 Auto unbypass - Zone list Zone list #
Open/Close Windows
Activation time 3 (During) is the only valid choice for these commands.
Action Code Action Specifier
40 Enable Opening Window by partition Partition(s)
41 Enable Closing Window by partition Partition(s)
42 Enable Access Window for access group Access Group
50 Off-Normal Reminder None
(Starts local keypad beeping if fire off-
normal condition exists)