Section 22 – Data Field Descriptions
22-7
*50 SESCOA/RADIONICS SELECT
[0]
Enter 0 if Radionics format is to be used with hexadecimal 0-9, B-F reporting. Enter 1 if
Sescoa format is to be used with only numeric reporting (0-9). Note that selection
applies to both primary and secondary phone numbers.
*51 DUAL REPORTING
[0]
This field allows all reports to be sent to both primary and secondary phone numbers.
Enter 1 if all reports are to be sent to both primary and secondary phone numbers. If
used with Split Reporting option 1 (1*34), Alarms go to both primary and secondary
numbers, while all other reports go to secondary only. If used with Split Reporting
option 2, Alarms go to both lines, Open/Close and Test messages go to secondary only,
while all other reports go to primary.
*52 STANDARD/EXPANDED REPORT PRIMARY
Alm Rst Byp Trbl Opn/Cls Low Batt
Enter 0 for standard or 1 for expanded reporting for the primary phone number; default
is 0.
Note:
Expanded overrides 4+2 format.
*53 STANDARD/EXPANDED REPORT SECONDARY
Alm Rst Byp Trbl Opn/Cls Low Batt
Enter 0 for standard or 1 for expanded reporting for the secondary phone number;
default is 0.
Note:
Expanded overrides 4+2 format.
*56 USE ONLY LRR (LONG RANGE RADIO)
[0]
Enter 1 if the built-in dialer is not being used and only the LRR will be used to
communicate. Otherwise enter 0.
*57 USE LRR (LONG RANGE RADIO) IF DIALER FAILS
[0]
Enter 1 if LRR is to be used as a backup to the built-in dialer if the dialer fails. The
radio messages begin transmitting the same time as the dialer. Once the dialer receives
a kissoff, the LRR will stop transmitting no matter where it might be within its
sequence. Otherwise enter 0.
*58 LONG RANGE RADIO CENTRAL STATION #1 CATEGORY ENABLE
Alm
Trbl
Byp
Opn/ClsSyst Test
Enter
1
to enable reports for primary Subscriber ID of Long Range Radio. Otherwise,
enter
0
. Default = 0.
*59 LONG RANGE RADIO CENTRAL STATION #2 CATEGORY ENABLE
Alm
Trbl
Byp
Opn/ClsSyst Test
Enter
1
to enable reports for secondary Subscriber ID of Long Range Radio. Otherwise,
enter
0
. Default = 0.