VISTA-128B Installation Instructions
6-6
If the following is displayed instead, press the [] key to display the faulted zone(s).
DISARMED Press
to show faults
Restore any faulted zone(s) as necessary (also make sure that you have connected a 2000-
ohm EOL resistor across the terminals of unused zones). When the
“DISARMED...READY TO ARM” message is displayed, you can proceed to the next step.
3.
Fault and then restore every contact or sensor on each zone individually to ensure that it
is being monitored by the system. Each time a zone is faulted, the keypads in the
partition to which the zone is assigned should display the number of the faulted zone.
Tripping fire and panic zones will cause external sounders to sound and may
trigger the dialer. When each zone is restored, the “READY TO ARM” message should
appear again.
If a zone or zones are not displayed at the correct partition's keypad(s), check both keypad and
zone programming to verify the correct partition assignment.
When you get the proper displays on the keypad(s), the hardwired zones in the system are
functioning properly.
4.
Power down and continue to the next section.