VISTA-128B Installation Instructions
22-16
2*06 AUTO-ARM WARNING PERIOD (partition-specific) [15]
|
Enter the time 01-15 in one-minute increments during which the user is warned by a
keypad sounding and display to exit the premises prior to auto arming of the system.
Enter
00
to disable the warning period.
2*07 AUTO-DISARM DELAY (partition-specific) [15]
|
Enter the time between the end of the disarming window and the start of auto
disarming of the system in values of 01-14 times 4 minutes.
Enter 00 if no delay is desired.
Enter 15 if auto disarming is not desired.
2*08 FORCE ARM ENABLE (FOR AUTO-ARM) (partition-specific)
[0]
Enter 1 if the system should automatically bypass any faulted zones when it attempts to
auto arm. Otherwise enter 0.
2*09 OPEN/CLOSE REPORTS BY EXCEPTION (partition-specific)
[0]
Enter 1 if Open/Close reports are to be sent only if the openings/closings occur outside
the arm and disarm windows. Open reports will also be suppressed during the closing
window in order to prevent false alarms if the user arms the system, then reenters the
premises to retrieve a forgotten item. Note that openings and closings are still recorded
in the event log. Enter 0 if exception reporting is not desired. Note: This field must be
set to
1
if No Opening and No Closing reports are to be sent.
2*10 ALLOW DISARMING ONLY DURING ARM/DISARM WINDOWS (partition-specific)
[0]
Enter 1 if disarming of the system should be allowed only during the arming/disarming
windows, or if the system is in alarm (if 2*11 is set to 1). Note that this applies only to
operator level users. Installer, Master and Manager level users can disarm the system
at any time. Enter 0 if disarming can occur at any time.
0=disable for displayed partition;
1
=enable for displayed partition
2*11 ALLOW DISARM OUTSIDE WINDOW IF ALARM OCCURS
[0]
Used only if field 2*10 (partition-specific field) is set to 1.
Enter 1 to allow the system to be disarmed outside the programmed disarm (opening)
window if an alarm has occurred.
Enter 0 to allow disarming only during the disarm window, regardless of system status.
If field 2*10 is set to 0 for a partition, this field (2*11) has no effect for that partition.
2*18 ENABLE GOTO FOR THIS PARTITION (partition-specific)
[0]
Enter 1 if this partition is to be accessed from another partition's keypad using the
GOTO command. Otherwise enter 0.
2*19 USE PARTITION DESCRIPTOR
[0]
Enter 1 if partition descriptors will be programmed. If enabled, the normal keypad
display will include a partition number and four-digit descriptor).
Enter 0 to cause the keypads to display a nonpartitioned system type of display (no
partition number will appear).
2*20 ENABLE J7 TRIGGERS FOR PARTITION (partition-specific)
[1]