VISTA-128B Installation Instructions
23-2
ZONE PROG?
0=No 1=Yes
For programming the following:
Zone number
Zone response type
Partition number for zone
Dialer report code for zone
Input device type for zone (whether RF, polling loop, etc.)
Enrolling serial numbers of 5800 Series transmitters and
serial polling loop devices into the system (all other zone
characteristics must be pre-programmed).
SEQUENTIAL LEARN?
0=No 1=Yes
For programming the following:
Input device type for zone (whether RF, polling loop, etc.)
Enrolling serial numbers of 5800 Series transmitters and
serial polling loop devices into the system (all other zone
characteristics must be pre-programmed).
REPORT CODE PROG?
0=No 1=Yes
For programming the following:
Alarm report codes for zones
Restore and supervisory codes
All other system report codes
ALPHA PROG?
0=No 1=Yes
For entering alpha descriptors for the following:
Zone descriptors
Installer's message
Custom words
Partition descriptors
Relay descriptors
DEVICE PROG?
0=No 1=Yes
For defining the following device characteristics for addressable
devices, including keypads, RF receivers (5881), 4204 Output
Relay Modules, 4285/4286 VIP Module and VGM:
Device address
Device type
Keypad options (including partition assignment)
RF House ID
RELAY PROG?
0=No 1=Yes
For defining output relay functions.
RLY VOICE DESCR?
0=No 1=Yes
For entering voice descriptors for relays to be used with the
4285/4286 VIP Module.