To load communication defaults, do the following:
Enter Program Mode [Installer Code] + 8 0 0 0. Once the Programming Mode is entered,
first press *94 and then enter one of the following field numbers:
TABLE OF DEFAULT PROGRAMMING COMMANDS
PRESS TO LOAD THIS DEFAULT PROGRAM SET
*80 Low Speed communication defaults
*81 ADEMCO 4 + 2 Express communication defaults
*82 ADEMCO High Speed communication defaults
*83 Contact ID communication defaults
Loading communication defaults results in the following:
Low Speed
(*94*80)
• Selects low speed, standard format, with no checksum, for both phone numbers.
• Assigns the following report codes:
03 for zones 002-047, 056-061, 064-128
01 for zones 001, and 048-055 (fire zones)
02 for zones 062,063 (panic transmitter), & 995, 996, 999 (keypad panics)
09 for all alarm restores
• Enables all zone type restores.
• For "expanded" reporting, enable fields *52 and *53.
ADEMCO
Express
(*94*81)
• Selects ADEMCO Express reporting format, with checksum, for both phone numbers.
• Report codes for zones 001-128, RF receiver, and keypad panics are sent as their
respective zone ID numbers. Duress is sent as "DD.” Alarm restore is "E" + 2nd digit.
• Enables all zone type restores.
ADEMCO
High
Speed
(*94*82)
• Selects ADEMCO High Speed format with no checksum, for both phone numbers.
• Zone reporting is assigned to channels as described later in this section.
• Enables all zone type restores.
• Enables duress to be sent.
ADEMCO's
Contact
ID
(*94*83)
• Selects Contact ID format for both phone numbers.
• Reporting is enabled for all zones.
• Enables all zone type restores.
• Refer to the Table of Contact ID Event Codes to follow.