4-1
SECTION 4
Installing The Control
•••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
♦
Mounting the Control Cabinet
♦
Installing the Cabinet Lock
♦
Grade A Mercantile Premises Listing
♦
Grade A Mercantile Safe and Vault Listing
♦
Installing the Control’s Circuit Board
♦
Connecting the AC Transformer and Battery
♦
Panel Earth Ground Connections
•••••••••••••••••••••••••••••••••••••••••••••••••
Mounting the Control Cabinet
• Mount the control cabinet to a sturdy wall using fasteners or anchors (not supplied) in a
clean, dry area which is not readily accessible to the general public. The back of the
control cabinet has 4 holes for this purpose.
• Before mounting the circuit board, remove the metal knockouts for the wiring entry that
you will be using. DO NOT ATTEMPT TO REMOVE THE KNOCKOUTS AFTER THE
CIRCUIT BOARD HAS BEEN INSTALLED.
Installing the Cabinet Lock
Use an ADEMCO No. N6277 Cam Lock and No. P3422-2 Clip for universal commercial
cabinet.
CABINET DOOR BOTTOM
RETAINER
CLIP
RETAINER CLIP
(NOTE POSITION)
RETAINER
SLOTS
LOCKED
UNLOCKED
Figure 4-1: Installing the Lock
1. Insert the key into the lock. Position
the lock in the hole making certain
that the latch will make contact with
the latch bracket when the door is
closed.
2. While holding the lock steady, insert
the retainer clip into the retainer
slots.