Section 22 – Data Field Descriptions
22-5
*36 DOWNLOAD ID NUMBER
||||||||
Enter eight digits, 00-09; A-F (10-15). Only applicable if downloading will be utilized.
Make entries as 2-digit numbers as follows:
00=0 02=2 04=4 06=6 08=8 10=A 12=C 14=E
01=1 03=3 05=5 07=7 09=9 11=B 13=D 15=F
*37 DOWNLOAD COMMAND ENABLES
Dialer
Shutdown
System
Shutdown
Not
Used
Remote
Bypass
Remote
Disarm
Remote
Arm
Upload
Program
Download
Program
Each of the various remote functions can either be enabled or disabled through V-LINK
or Compass downloading software. Disabling a function means that you will not be able
to perform that function from the V-LINK or Compass.
Enter 1 to enable a function, enter 0 to disable. See field 1*53 to disable the download
callback option. For UL commercial burglary installations, all entries must be 0.
*38
PREVENT ZONE XXX BYPASS
(partition-specific) [000]
||
Entering a zone number (001-128) prevents that zone from being bypassed by the user.
Enter 000 if this feature is not desired (all zones can be bypassed).
*39
ENABLE OPEN/CLOSE REPORT FOR INSTALLER CODE
(partition-specific)
[1]
Enter 1 if Open/Close reporting for the installer is desired.
Otherwise enter 0.
*40 OPEN/CLOSE REPORTING FOR KEYSWITCH
[0]
Enter
1
to enable Open/Close reporting for the keyswitch.
Enter
0
if reporting is not desired.
*41 NORMALLY CLOSED OR EOLR (ZONES 2-8)
[0]
Enter 0 if end-of-line resistors are to be used.
Enter 1 if end-of-line resistors are not to be used, in which case only normally closed
devices must be used.
Must be 0 for UL installations.
*42
DIAL TONE PAUSE
[0]
This field sets the time the system will wait for dial tone before dialing. Applies if true
dial tone is not selected in field *43.
Enter the desired wait time for dial tone detection as follows: Enter single digit: 0 = 5
seconds; 1 = 11 seconds; or 2 = 30 seconds. Must be 0 for UL installations.