VISTA-128B Installation Instructions
23-24
The 6139 Keypad will display the following prompts, which are sent by the Long Range
Radio transmitter to the control.
DEVICE ADDRESS
Enter the device address of the radio. The default address is 3.
ID #
(1234)
Enter the 4-digit customer account number,
0001-9999
. This
ID number will appear in the messages generated by the radio.
Messages generated by the panel and transmitted by the radio
will contain the ID number programmed into the panel. The
radio and the panel should have the same ID number, if
possible.
If a different 4-digit customer account number is used in the radio than is programmed into the
alarm control, the radio will transmit radio-specific messages (power-on reset, AC fail, etc.) using
the radio customer number, and alarm messages using the control panel’s customer number. If
these numbers are different, you will be billed for two AlarmNet radio accounts.
ODD [Y/N]
(N)
Enter
Y
for odd system flag;
N
for even system flag.
Alarmnet (Y/N)
(Y)
Enter
Y
if an AlarmNet installation. Enter
N
for private
system users (skip to Question 7).
CS ID
(11)
Enter the primary central station’s system ID number,
1-7F
(will not be displayed for private system users).
BAT PRESENT [Y/N]
(N)
Enter
Y
if optional battery will be used.
Must be Y for UL
installations (a battery must be installed).
USE RADIO # [Y/N]
(N)
If
Y
is selected, the Radio ID number will replace the panel
Subscriber ID in panel-generated messages with the Radio ID
number.
If
N
is selected, the radio will send panel-generated messages
with the panel Subscriber ID number.
2
ND
CS ID
(12)
This must be programmed with a value, even if it is the
same as the primary central station.
The alarm panel has
the option to send a selected message to the second central
station.
REVIEW (Y/N)
(N)
Enter
Y
to review the programming options and to ensure that
the correct responses have been made. Parameters can be
changed during review.
Enter
N
to end programming session.