VISTA-128B Installation Instructions
12-6
Faulted zones must either be corrected or bypassed before the system will arm.
With Alarms Present:
A momentary short across Zone 7 will silence alarm bell and keypad sounds, and will disarm
the system if it was armed. The keyswitch LEDs provide a memory of alarm indication (see
table below). A subsequent short across Zone 7 will clear the alarm memory indication and
reset 2-wire smoke and glassbreak detectors (if used).
LED indications are defined as follows:
GREEN RED MEANING
OFF OFF DISARMED & NOT READY
ON OFF DISARMED & READY
OFF ON STEADY ARMED AWAY
OFF SLOW FLASH ARMED STAY
OFF RAPID FLASH ALARM MEMORY
If Open/Close reporting for the keyswitch is enabled in field *40, the keyswitch reports as user 0.
Audio Alarm Verification (AAV) Equipment
An Audio Alarm Verification (AAV) Module (also known as two-way voice), such as the Eagle
1250, is an add-on accessory that permits voice dialog between an operator at a central
station and a person at the alarm installation, for the purpose of alarm verification. This
feature is supported only if Alarm reports are programmed to be sent to the primary phone
number. For a detailed explanation on the operation and wiring of the AAV, see the Audio
Alarm Verification section.
Auxiliary Alarm Signaling Equipment
The J7 connector can be used to provide triggers for the following conditions:
•
Fire alarm
•
Burglary/audible panic alarm
•
Silent panic/duress alarm
•
Opening/closing (arming/disarming)
These triggers may be used to trip auxiliary alarm signaling equipment such as ADEMCO's
7720, 7720ULF, and 7920SE Long Range Radios.
The open/close, fire alarm, burglary/audible panic alarm, and silent panic/duress alarm
triggers are common to all partitions and must be enabled for each partition (data field 2*20).
The open/close trigger is LOW when all enabled partitions are armed, and HIGH when any
enabled partition is disarmed. The remaining triggers are normally LOW and go HIGH
when the corresponding condition occurs in at least one enabled partition. The fire and
burglary/audible panic alarm triggers remain HIGH until a [User Code] + OFF is entered in
all enabled partition(s) which display these conditions. The silent panic/duress trigger works
the same way, except that it is momentary when initiated by duress.