VISTA-128B Installation Instructions
4-2
U
L
To provide certificated burglary service for UL installations, refer to the special requirements and
Figure 4-2 Cabinet Attack Resistance Considerations
to follow.
Grade A Mercantile Premises Listing
The panel door must be supervised. Mount the clip-on tamper switch (supplied) to the
cabinet's right side wall as shown in the diagram below, and wire it to one of the
hardwire zones.
Use a bell with a tamper-protected housing such as the ADEMCO AB12. The bell
housing's tamper switch and inner tamper linings must also be wired to the hardwire
zone.
Assign the hardwire zone to a burglary partition. Program the hardwire zone for day
trouble/night alarm (zone type 5) when only one burglary partition is used. Program it
for 24-hr. audible alarm (zone type 7) when more than one burglary partition is used.
All wiring between the bell and panel must be run in conduit. Remaining wires do not
need to be run in conduit.
All wiring which is not run in conduit must exit from the knockout openings on the
bottom or back of the cabinet.
All unused knockouts must be plugged using the disc plugs and carriage bolts (supplied),
as indicated in the diagram below.
Fasten the cabinet door to the cabinet backbox using the 18 one-inch-long Philips-head
screws (supplied) after all wiring, programming and checkout procedures have been
completed.
CABINET ATTACK RESISTANCE CONSIDERATIONS
(Shows typical local Grade A listing installation)
C-COM
PCB
1
1
RUN BELL WIRES
IN CONDUIT
PLUG THIS
KNOCK-OUT
CLIP-ON DOOR
TAMPER SWITCH
CABINET
MOUNTING HOLE
(4 PLACES)
PLUG THIS
KNOCK-OUT
PLUG THIS
KNOCK-OUT
PLUG THIS
KNOCK-OUT
RUN ALL REMAINING
WIRES THRU HERE
TO PLUG AN UNUSED KNOCKOUT OPENING, REMOVE KNOCKOUT AND
INSTALL A PAIR OF DISC PLUGS AND A CARRIAGE BOLT AS SHOWN:
KNOCK-OUT
OPENING
DISC PLUGS (DIMPLES IN DISC
PLUG SHOULD REGISTER INSIDE
KNOCK-OUT OPENING
CARRIAGE BOLT
HEX NUT AND
LOCK WASHER
CABINET SIDEWALL
(OUTSIDE)
Figure 4-2: Cabinet Attack Resistance Considerations