VISTA-128B Installation Instructions
11-4
Programming Audio Alarm Verification Module Options
1. With at least one 2-line alpha keypad (6139) wired and set to a proper address,
temporarily apply power to the system.
2. Enter Data Field Programming Mode: [Installer Code] + 8 0 0 0.
3. Program the following data fields:
*45 PRIMARY DIALER FORMAT: Set for 1 (Contact ID).
1*46 AUXILIARY OUTPUT ENABLE: Set for 3 (unless using 4204 Relay Module).
1*60 ZONE 5/AUDIO ALARM VERIFICATION: Set for 1.
Set CANCEL REPORT to a non-zero digit in System Group #1 in Report Code Programming
in the #93 Menu Mode.
If you need more information about actual programming procedures, see
The Mechanics of
Programming
section.
4. Zone 5 must be programmed for response type 10 and the EOLR must be removed,
regardless of whether or not EOLRs have been enabled in field *41. Zone 5 is no
longer available as a protection zone.
5. If using a 4204 relay instead of the J7 trigger, program the relay to trip on Zone
Type/Sys. Op. 60 Audio Alarm Verification (see the Relay Outputs and Powerline Carrier
Devices section).
6. Press *99 to exit Program Mode.