Section 22 – Data Field Descriptions
22-11
1*20 EXIT ERROR LOGIC ENABLE
[0]
Enter 1 to enable Exit Error Logic (entry/exit doors and interior zones will be bypassed
if left open).
Enter 0 if Exit Error Logic is not desired. Must be 0 for UL commercial burglary
installations.
1*21 EXIT DELAY RESET
[0]
Enter 1 to reset exit delay to 60 seconds after door is closed.
Enter 0 if exit delay not to be reset. Must be 0 for UL commercial burglary installations.
1*22 CROSS ZONING PAIR ONE
|
|
Enter the first pair of zones, which must both be faulted within a five-minute period to
cause an alarm.
Enter
00,00
to disable. Must be 00,00 for UL burglary installations.
1*23 CROSS ZONING PAIR TWO
|
|
Enter the second pair of zones, which must both be faulted within a five-minute period
to cause an alarm.
Enter 00,00 to disable. Must be 00,00 for UL burglary installations.
1*24 CROSS ZONING PAIR THREE
|
|
Enter the third pair of zones, which must both be faulted within a five-minute period to
cause an alarm.
Enter 00,00 to disable. Must be 00,00 for UL burglary installations.
1*25 CROSS ZONING PAIR FOUR
|
|
Enter the fourth pair of zones, which must both be faulted within a five-minute period to
cause an alarm.
Enter 00,00 to disable. Must be 00,00 for UL burglary installations.
1*26 PANIC BUTTON OR SPEEDKEY [00,00,00,00]
|
|||
ABCD
For each lettered key A-C, enter 00 to assign that key’s respective panic function, or
enter a speedkey macro number
01-32
to assign a particular macro to that key. For the
D
key, enter 00 to use the
D
key to select a macro to execute when key is pressed, or
enter a macro number
01-32
to execute a particular macro with the
D
key.
Instead of the 32 macros, each key can be programmed for any of 3 other functions.
Choice 33
= fire sounder silence. The key, when pressed, will silence fire alarms.
Choice 34
= display next fire alarm. The key, when pressed, will display the next fire
alarm present in the system.
Choice 35
= display previous fire alarm. The key, when pressed, will display the
previous fire alarm present in the system.
Note:
Choices 34 and 35 should be used in conjunction with field 1*10 Fire Display
Lock.