VISTA-128B Installation Instructions
9-2
Wiring the 4204 and 4204CF Relay Modules
1. Set the 4204 or 4204CF's DIP switches for a device address between 01-15 that is not
being used by another device (keypads, RF receivers, etc.).
The relay module will not operate until the device address you have chosen is enabled in the
control's
Device Programming
in the
#93 Menu Mode
.
2. Mount the 4204 and 4204CF Modules as per the instructions provided with these
modules. Connect the 4204/4204CF Module(s) to the control's keypad terminals (6-9)
when mounted remotely from the control. Use the flying lead cable or the screw
terminals provided with each relay module to make connections.
3. When mounted remotely, homerun each module to the control. The table below shows the
maximum wire run lengths from the control to each 4204. Refer to the instructions
provided with the 4204CF for its maximum permissible wire lengths.
Wire Gauge Maximum Length
#22 125 feet
#20 200 feet
#18 300 feet
#16 500 feet
SWITCH 4 2 0 4 A DDRESS SETTINGS
POSITION ("—" means "OFF")
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
2
ON ON ON ON ON ON ON ON
3
ON ON ON ON ON ON ON ON
4
ON ON ON ON ON ON ON ON
5
ON ON ON ON ON ON ON ON
ON
12345
13 14 15 16
C
NC
NO
OFF
ON
DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER
COVER TAMPER (REED) SWITCH
TB1
4204
TB2
4-PIN CONSOLE PLUG
121110987654321
C
NC
NO
C
NC
NO
C
NC
NO
RELAY
3
RELAY
2
RELAY
1
RELAY
4
TYPICAL
(SHOWN "OFF")
EITHER OR BOTH
CAN BE USED
DATA IN
FROM CONTROL
(–) GROUND
DATA OUT
TO CONTROL
(+) 12V
YEL
BLK
GRN
RED
Figure 9-1: 4204 Relay Module