VISTA-128B Installation Instructions
10-2
Mounting the VIP Module
The VIP Module may be mounted in the control cabinet if space is available or, if this is not
possible, on the side of the cabinet or adjacent to it. Pry off the VIP Module's cover prior to
wiring.
1. When the VIP Module is mounted inside the control cabinet, attach it to the cabinet's
interior surface with 2-faced adhesive tape. You may leave the module's cover off if it is
mounted within the cabinet.
Do not mount the VIP Module on the cabinet door or attempt to attach it to the PC board.
2. When the module is to be mounted outside the cabinet, use the screw holes at the rear to
mount horizontally or vertically (2-faced adhesive tape may be used, if preferred). You
can bring wires out from the side or back (a round breakout is also available on the back).
When you complete the Module's mounting and wiring, you should install the module's
cover (with label affixed, as indicated next).
3. Affix the 4285/4286 connections label (supplied separately) to the inside of the VIP
Module's cover if the cover is used. Otherwise, affix the label to the inside of the control
cabinet's door.
Wiring the VIP Module
The 4285/4286 is wired between the control panel and the premises’ handset(s) (see Figure
10-1). It listens for TouchTones on the phone line and reports them to the control panel.
During on-premises phone access, it powers the premises phones; during off-premises phone
access, it seizes the line from the premises phones and any answering machines.
1. Make 12V (+) and (–) and data-in and data-out connections from the VIP Module to the
control*, using the connector cable supplied with the VIP Module. These are the same
connections as for remote keypads.
2. Insert the keyed connector at the other end into the mating header on the VIP Module.
3. Connect terminals 1 through 7 on the VIP Module as shown.
Terminal Block Connections
4285/4286 Terminal Connects to:
1. Phone In (Tip)
green wire of direct connect cord
2. Phone In (Ring)
red wire of direct connect cord
3. Phone Out (Tip)
brown wire of direct connect cord
4. Phone Out (Ring)
gray wire of direct connect cord
5. No Connection
6. Audio Out 1
Speaker
7. Audio Out 1
Speaker
Supported by the 4286 only
Vista de pagina 67