VISTA-128B Installation Instructions
24-2
Auto Arming
• The system can automatically arm (AWAY Mode) a partition at the end of a pre-
determined closing (arming) time window.
• Auto arming can be delayed three ways: by use of the auto arm delay, the auto arm
warning, or by manually extending the closing (arming) time window with a keypad
command.
• The system can also automatically bypass any open zones when auto arming.
Auto-Arm Delay
• Auto-arm delay provides a delay (grace period) before auto arming.
• It starts at the end of the closing time window.
• The delay is set in 4-minute increments, up to 56 minutes in partition-specific program
field 2*05.
• At the expiration of this delay, the auto-arm warning will start.
Auto-Arm Warning
•
The auto-arm warning causes the keypad sounder to warn the user of an impending
auto-arm.
•
The warning can be set from 1 to 15 minutes prior to the arming in partition-specific
program field 2*06.
•
During this period the keypad beeps every 15 seconds and displays "AUTO ARM
ALERT.” During the last 60 seconds, the keypads begin to beep every 5 seconds.
•
The panel arms at the conclusion of the auto-arm warning period.
Extend Closing Window
• A user can manually delay the arm (closing) time window by 1 or 2 hours.
• This is done by entering a keypad command ([User Code} + #82), which then prompts the
user to enter the desired extension time of 1 or 2.
• This feature is useful if a user must stay on the premises later than usual.
• The auto-arm delay and warning periods will begin at the end of the extension.
Force Arm
• The force arm option causes the panel to attempt to bypass any faulted zones prior to
auto-arming (panel will perform a force-arm).
• This option is set in partition-specific program field 2*08.
Auto Disarming
• The system can automatically disarm a partition at the end of a pre-determined opening
(disarm) time window.
• The disarming time can be delayed by using the auto-disarm delay feature.
Disarm Delay
• Auto-disarm delay provides a delay before auto disarming. This delay is added to the end
of the disarm time window.
• The delay is set in 4-minute increments, up to 56 minutes, in partition-specific program
field 2*07.