VISTA-128B Installation Instructions
18-2
Failure to observe the polling loop current rating will cause polling loop malfunction. Failure to
observe the auxiliary power current rating will result in a battery that does not charge properly or
possibly a tripped circuit breaker.
2. Connect all installed devices to the control.
3. Wire the 1361 Transformer (1361CN in Canada) to the panel (before connecting the
battery) as shown in Figure 18-1, or wire the 4300 Transformer as shown in Figure 18-2
(if using Powerline Carrier devices).
4.
Plug the transformer into a 24 hour, uninterrupted, 120VAC, 60Hz outlet. After a few
seconds, the keypad display will appear.
NO CONNECTION
TRANSFORMER
16.5VAC, 40VA
ADEMCO No.1361
or 4300, XM10E, or
XF10 if X-10 DEVICES
WILL BE USED.
Connect to
24hr. source
of AC mains
123
RED (+)BLK (-)
Connect to
12VDC, 4AH
or 12VDC, 7AH
GEL CELL
BATTERY
CHARGING
VOLTAGE
13.7 VDC
NOTE:
WHEN POWERING UP
THE PANEL, PLUG THE
TRANSFORMER IN BEFORE
CONNECTING THE BATTERY.
BATTERY
TABS
PRIMARY
POWER
Supplied by a
transformer which
is rated at
16.5VAC, 40VA.
Caution must be
taken when wiring
this transformer to
the panel to guard
against blowing the
fuse inside the
transformer (non-
replaceable).
Figure 18-1: 1321 Transformer and Battery Connections
123456789
GROUND
GROUND
OUT 6
IN 2
GROUND
IN 3
GROUND
OUT 5
J8 CONNECTOR
BLACK
BLUE
BROWN
GREEN
RED
WHITE
YELLOW
GRAY
VIOLET
4142TR CABLE
1
2
3
4
56
TB1
-1
TB1
-30
TB1
-2
AC
Earth
Ground
AC
Sync
Data
Com
4300 TRANSFORMER/INTERFACE
Figure 18-2: 4300 Transformer Connections