ADEMCO Vista 4130XT Manual de instrucciones Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 84
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
r-
seconds A system-wide EEPROM defined number of alarm
reports for this zone will be allowed to retransmitted (swinger sup-
pression) by the communicator in one armed period, The
communicator will transmit a restoral message when the zone
is restored for a time greater than its physical response time
(less than 1 second).
During the disarmed state, a faulted zone will result in a NOT
READY dwplay. Subsequent depression of the READY key will
cause all the faylted zones to be sequentially displayed, No
communicator reporls will be initiated,
Type 5. BURGLARY PERIMETER, TROUBLE BY DAY/ALARM BY
NIGHT: During the disarmed state (day), faulting the zone will
initiate a “trouble” display and a latched sounder (beeping).
The Control will beep rapidly along with a latched display of the
faulted zone and the word CHECK, Pressing any key will
silence the beeping for 10 seconds. Code + OFF will silence
the beeping but will only clear the display of a zone that had
the fault condition removed.
If a Communication board is used, each trouble will result in a
“trouble” report (if programmed). A trouble restoral message
will be sent as each zone is restored to normal condition. The
maximum number of trouble reports per armed period will be
limited by the system-wide EEPROM number of alarm reports
option (swinger suppression).
During the armed state (night), the local (Control) and external
(if used) alarm sounder will activate and the communicator will
report alarms. A system-wide EEPROM defined number of
alarm reports for this zone will be allowed to be transmitted in
one armed period, Restorals will be sent when the zone is re-
stored for a time greater than its physical response time (less
than 1 second).
Type 6. 24-HOUR SILENT ZONE Sensors assigned to this zone,
when faulted, will initiate a communicator report. There will be
no local displays or alarm sounds. Upon keying Code plus OFF,
there will be a memory indication of the faulted zone.
A system-wide EEPROM defined number of alarm reports for
this zone will be allowed to be transmitted (swinger suppres-
sion) by the communicator until an OFF sequence is per-
formed. The communicator will transmit a restoral message
when the zone is restored for a time greater than its physical
response time (less than 1 second).
During the disarmed state, NOT READY will be displayed if a
sensor is faulted. The burglary portion of the system cannot be
armed if this zone is faulted. An OFF sequence (code plus OFF)
should be performed prior to arming the system or viewing the
faulted zones via the *key,
Type 7. 24-HOUR AUDIBLE ZONE: Faulting a zone of this type will
initiate a loud audible alarm externally and at the Control, an
LCD display, and a (EEPROM selected) communicator report.
Pressing any key will silence the Control sounder for 10
seconds. Keying Code plus OFF will permanently silence the
alarm. A system-wide EEPROM defined number of alarm
reports for this zone will be allowed to be transmitted (swinger
suppression) by the communicator until an OFF sequence is
performed The communicator will transmit a restoral message
when the zone is restored for a time greater than its physical
response time (less than 1 second).
Type 8. 24-HOUR AUXILIARY ZONE Faulting a zone of this type will
initiate a steady alarm sound at the Control, an
ALARM display, and a (EEPROM selected) communicator
report. Pressing any key will silence the Control sounder for 10
seconds. Keying Code plus OFF will permanently silence the
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 83 84

Comentarios a estos manuales

Sin comentarios