For each zone used, one of the following zone types must be selected:
7
1. Entry/Exit Burglary (Delay #1). Assigned to sensors on doors
through which entry and exit WIII normally take place when the sys-
tem E armed.
B
2. Entry/Exit Burglary (Delay #2). May be set for different delay than
above. For use with sensors on overhead garage doors, etc., where
longer delay w needed to reach the keypad in the main portion of the
house or building, and more delay is needed to exit the premises.
3. Perimeter Burglary. Normally assigned to all sensors on exterior
doors and windows requiring mslant alarm.
9
4 lntetior, Follower. Delay edalarm only ifthe Entry /Exit zone is
10
faulted first otherwise, produces an instant alarm. Assigned to zone
covering an area such as a foyer or lobby through which one must
pass upon entry toreach thekeypad todisarm the system Designed
to provide instant intrusion alarm in the event an intruder hides on the
premrses prior to the system being armed or gatns access to the
premises through an unprotected area.
5. Trouble by Day/Alarm by night. Can be assigned to a zone which
contains a foil-protected door or window (such as in a store), or to a
zone covering a “sensitwe” area such as a stock room, drug supply
room, etc., or other controlled access area where immediate
notification of an entry M desired. During the disarmed state (day), the
system will prowde latched Control/Console annunciation (and cen-
tral station report, if desired) of openings or troubles (such as sensor
malfunctions or foil breaks), During the armed state (night), violations
will initiate an alarm.
6. 24-hour Silent Alarm. This type generally assigned to a zone con-
taining an Emergency button that is designed to initiate an alarm
report to the Central Station, but which produces no local displays or
alarm sounds.
24-hour Audible Alarm. This type also assigned to a zone contain-
ing an Emergency button, but which will initiate an audible alarm in
addition to an alarm report to the Central Station.
24-hour Auxiliary Alarm (Control internal sounder only). This type
assigned to a zone containing a button for use in personal emer-
gencies, or to a zone containing monitoring devices such as water
sensors, temperature sensors, etc Designed to initiate an alarm
report to the Central Station and also provide Control/Console alarm
sounds and alarm displays.
Supervised Fire (alarm on short/trouble on open).
Interior that always has Entry/Exit Delay #1 (except that Entry
delay is suppressed in the INSTANT mode). This type Iypicaliy
assigned to an interior zone containing a PIR that covers an area
through which the user must pass to reach the Control for disarming
purposes (whether inside or first entering). Ideal for an area such as
an apartment entrance foyer in which a keypad is located.