ADEMCO VISTA 10 Manual de usuario

Busca en linea o descarga Manual de usuario para Los Sistemas De Control De Acceso De Seguridad ADEMCO VISTA 10. ademco vista-10p ademco vista-10psia [en] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
ADEMCO VISTA-10P
ADEMCO VISTA-10PSIA
Security Systems
Programming Guide
K0735PRV3 10/04 Rev. B
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - ADEMCO VISTA-10PSIA

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems Programming Guide K0735PRV3 10/04 Rev. B

Pagina 2 - TO ENTER PROGRAMMING MODE:

– 10 – *80 OUTPUT DEFINITION MODE (press ∗∗∗∗80 while in Data Programming mode) Output Funct. # (00 = Quit) 01 Enter the output function number to b

Pagina 3 - DATA FIELD PROGRAMMING FORM

– 11 – 01 Delete Zone? 0 = No 1 = Yes 0 0 = don’t delete zones; save zone list and return to the Zone List No. prompt. 1 = go to next prompt t

Pagina 4 - VISTA-10PSIA

– 12 – Adding Custom Words (will not be annunciated by 4285/4286 Phone Module) Program Alpha ? 0=No, 1=Yes 0 The “Program Alpha ?” prompt will appea

Pagina 5 - Enable Sound

– 13 – CHARACTER (ASCII) CHART (For Adding Custom Words) 32 (space) 33 ! 34 " 35 # 36 $ 37 % 38 & 39 ' 40 ( 41 ) 42 * 43 + 44 , 45 – 4

Pagina 6 - OPEN SHORTEDINTACT

– 14 – SCHEDULE WORKSHEET (installer code + [#] + [6] [4]; master code can only access schedule 01 and events 00-07) No. Event Device No. Group

Pagina 7 - TO CONFIRM

– 15 – OUTPUT RELAYS WORKSHEETS FOR ∗∗∗∗79, ∗∗∗∗80 and ∗∗∗∗81 (Applicable only if Relays are to be used) ∗∗∗∗79 RELAY MAPPING WORKSHEET (Must progra

Pagina 8 - AXXX-XXX –

5800 Series Transmitter Input Loop Identification 5802MNENROLL AS"UR" OR "RF"LOOP1V20P-006-V05817ENROLL AS "RF"5890ENR

Pagina 9

– 2 – TO ENTER PROGRAMMING MODE: Local programming requires the use of an alpha keypad connected to the keypad terminals on the control. A. POWER UP

Pagina 10 - *80 OUTPUT DEFINITION MODE

– 3 – DATA FIELD PROGRAMMING FORM Where noted, certain fields have special settings when used with the VISTA-10PSIA (indicated by heavy borders and r

Pagina 11

– 4 – ∗∗∗∗49 Split/Dual Reporting [0] 0 = Standard/Backup reporting only (all to primary unless fail) Primary Phone No. Secondary Phone

Pagina 12 - Italicized

– 5 – ∗∗∗∗90 Event Log Enables [3] NOTE:System messages are logged when any non-zero entry is made. 0 = None; 1 = Alarm/Alarm Restore; 2

Pagina 13 - SCHEDULING MODE

– 6 – CONFIGURABLE ZONE TYPES WORKSHEETS Configurable zone type 90 can be programmed via downloader software or from a keypad using data fields*182-

Pagina 14 - SCHEDULE WORKSHEET

– 7 – ∗∗∗∗56 ZONE PROGRAMMING MENU MODE (press *56 while in Program mode) SET TO CONFIRM? 0 = NO 1 = YES We recommend that you select “yes” to conf

Pagina 15

– 8 – Entd A022-4063 1 Rcvd A022-4064 1 If the serial number transmitted does not match the serial number entered, a display similar to the one

Pagina 16 - ÊK0735PRV36Š

– 9 – INPUT S/N L AXXX-XXXX – Manually enter the serial number printed on the label for the wireless key or press and relea

Comentarios a estos manuales

Sin comentarios