
– 2 –
TO ENTER PROGRAMMING MODE:
Local programming requires the use of an alpha keypad connected to the keypad terminals on the control.
A. POWER UP, then depress [
✱
] and [#] both at once, within 50 seconds of powering up )if
✱
98 was used to exit previously, this method
must be used to reenter program mode). OR
B. Initially, key: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0.
Data Field Programming Procedures
Task Procedure
Go to a Data Field Press [
∗
] + [Field Number], followed by the required entry.
Entering Data When the desired field number appears, simply make the required entry. When the last entry for a field is entered,
the keypad beeps three times and automatically displays the next data field in sequence.
If the number of digits that you need to enter in a data field is less than the maximum digits available (for example,
the phone number fields *41, *42), enter the desired data, then press [∗ ] to end the entry. The next data field is
displayed.
Review a Data Field Press [#] + [Field Number].
Data will be displayed for that field number. No changes will be accepted in this mode.
Deleting an Entry Press [
∗
] + [Field Number] + [
∗
]. (Applies only to fields
∗
40–*44, *94, and pager programming fields)
Interactive Menu Mode Programming (∗
∗∗
∗56, ∗
∗∗
∗57, ∗
∗∗
∗58, ∗
∗∗
∗79, ∗
∗∗
∗80, ∗
∗∗
∗81, ∗
∗∗
∗82)
See respective sections in this document for programming procedures.
Press [
✱
] + [Interactive Mode No.] (for example,
✱
56). The alpha display keypad will display the first of a series of prompts.
Interactive Menu Mode Used to Program
✱
56 Zone Programming Zone characteristics, report codes, alpha descriptors, and serial numbers for RF trans.
✱
57 Function Key Programming Unlabeled keypad keys (known as ABCD keys) for special functions
✱
58 Zone Programming Same options as *56 mode, but with fewer prompts. Intended for those familiar with
(Expert mode) this type of programming, otherwise *56 mode is recommended.
✱
79 Output Device Mapping Assign module addresses and map individual relays/powerline carrier devices
✱
80 Output Programming
4204 Relay modules, Powerline Carrier devices, or on-board triggers
✱
81 Zone List Programming
Zone Lists for relay/powerline carrier activation, chime zones, pager zones, etc.
✱
82 Alpha Programming
Zone alpha descriptors
INITIALIZE DOWNLOAD and RESET DEFAULTS
✱
96 Initializes download ID and subscriber account number.
✱
97 Sets all data fields to original factory default values.
TO EXIT PROGRAMMING MODE:
✱
98 Exits programming mode and
prevents
re-entry by: Installer Code + 8 + 0 + 0. If
✱
98 is used to exit programming mode,
system must be powered down, and method A above used to enter the programming mode.
See field *88 for other *98 Program mode lockout options.
✱
99 Exits programming mode and
allows
re-entry by: Installer Code + 8 + 0 + 0 or method A above.
Special Messages
OC = OPEN CIRCUIT (no communication between Keypad and Control).
EE or ENTRY ERROR = ERROR (invalid field number entered; re-enter valid field number).
After powering up, AC, dI (disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds. This will revert to
a “Ready” message in approximately 1 minute, which allows PIRS, etc. to stabilize. You can bypass this delay by pressing [#] + [0].
If E4 or E8 appears, more zones than the expansion units can handle have been programmed. The display will clear after you correct the
programming.
Table of Device Addresses
This Device Uses Address
Reports as
††
Enabled By…
RF Receiver 00 100 *56 zone programming: input device type entry
Long Range Radio 03 103 automatic if output to long range radio field *29 enabled
4286 Voice Module 04 104 automatic if phone module access code field *28 enabled
4204 Relay Module 12 112 *79 output device programming: entered at device address prompt:
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
16
17
18
19
20
21
22
23
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
data field programming as listed below:
always enabled, all sounds enabled.
data field *190
data field *191
data field *192
data field *193
data field *194
data field *195
data field *196
5800TM Module 28 n/a automatic
†† Addressable devices are identified by “1” plus the device address when reporting. Enter report code for zone 91 to enable addressable device
reporting (default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit identification keypad display options.
Comentarios a estos manuales