ADEMCO VISTA 10 Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
5
90 Event Log Enables
[3]
NOTE
:
System messages are logged when any non-zero entry is made.
0 = None; 1 = Alarm/Alarm Restore; 2 = Trouble/Trouble Restore
4 = Bypass/Bypass Restore; 8 = Open/Close.
Example: To select Alarm/Alarm Restore, and Open/Close, enter 9
(1 + 8); to select all, enter #15.
91 Option Selection [8, 0]
Options: 0 = None Options VISTA-10PSIA
4 = AAV UL: must use ADEMCO UVCM module Call Wait Disable
8 = Exit Delay Restart/Reset UL: must be disabled
#+12 = AAV and Exit Delay Restart/Reset
SIA Guidelines: Exit Delay should be enabled.
VISTA-10PSIA: Options: Same as listed above.
Call Waiting Disable:
0 = call waiting not used
1 = call waiting disable digits (*70) entered in field *40; (when
selected, the system dials the entry in field *40 only on
alternate dial attempts; this allows proper dialing in the event
call waiting service is later canceled by the user).
93 Reports In Armed Period [1,0]
Per Zone (Swinger Suppression) Restrict VISTA-10PSIA
Restrict Report Pairs: Report Pairs Unlimited
0 = Unlimited Reports; 1 = 1 report pair Reports Enable
2 = 2 report pairs SIA Guidelines: Must be set for option 1 or 2.
VISTA-10PSIA:
Restrict Report Pairs: 1 = 1 report pair; 2 = 2 report pairs
Unlimited Reports Enable:
0 = restrict reports to the setting in entry 1
1 = unlimited reports for zones listed in zone list 7; (use zone list 7
to enter those zones that require unlimited reporting; these
zones ignore the setting in entry 1)
DOWNLOAD INFORMATION
94 Download Phone No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits, 09; #+11 for '
'; #+12 for '#'; #+13 for a 2-second
pause. Do not fill unused spaces. If fewer than 20 digits, exit field by
pressing
. To clear entries, press
94
.
UL: downloading may be performed only if a technician is at the site.
95 Ring Count For Downloading
[15]
NOTE: Do not enter 0 if using 4285/4286 Phone Module.
0 = Disable Station Initiated Download;
114 = number of rings (19, # +10 =10, # +11 =11,
# +12 =12, # +13 =13, # +14 =14);
15 = answering machine defeat (# +15 =15).
96, *97 Initialize/Reset Defaults
(
These are commands, not data fields. See page 2
)
98, *99 Exit Commands
(
These are commands, not data fields. See page 2
)
PAGER OPTIONS
160 Pager 1 Phone No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. 09; #+11 = '
'; #+12 = '#'; #+13 = 2-sec pause.
161 Pager 1 Characters
| | | | | | | | | | | | | | |
Enter the optional prefix characters, up to 16 digits.
09; #+11 = '
'; #+12 = '#'; #+13 = 2-second pause.
162 Pager 1 Report Options
[0]
0 = no reports sent
1 = Opens/closes all users
4 = All alarms and troubles
5 = All alarms / troubles, and opens/closes for all users
12 = Alarms / troubles for zones entered in zone list 9
13 = Alarms / troubles for zones entered in zone list 9, and
opens/closes for all users
172 Pager Delay Option For Alarms
[3]
0 = none, 1 = 1 minute, 2 = 2 minutes, 3 = 3 minutes
This delay is for ALL pagers in the system.
MISCELLANEOUS SYSTEM FIELDS
177 Device Duration 1, 2 [0] [0]
(used in *80 Menu mode-Device Actions 5/6) 1 2
0 = 15 seconds 6 = 2-1/2 min #+11 = 7 min
1 = 30 seconds 7 = 3 min #+12 = 8 min
2 = 45 seconds 8 = 4 min #+13 = 10 min
3 = 60 seconds 9 = 5 min #+14 = 12 min
4 = 90 seconds #+10 = 6 min #+15 = 15 min
5 = 2 minutes
181 60 Hertz AC Operation
[0]
0 = 60 Hz; 1 = 50 Hz
CONFIGURABLE ZONE TYPE OPTIONS
182 Configurable Zone Type 90
1 2 3 4 5 6 7 8 9 10
Enter the appropriate value for each entry, 1-10, based on the charts
provided on the next page. Each entry is the sum of the values of its
selected options
(0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14, #+15=15).
UL: Do not configure zones as a fire alarm or UL burglar alarm zone.
183 Zone Type 90 Report Codes
IMPORTANT: Use existing Contact ID® codes, if appropriate, or
define unique codes in CID code range 750-789. See note in
installation instructions.
90 ALARM ID: XXX
TROUBLE ID: XXX
Enter the desired 3-digit Contact ID® report codes for alarms and
troubles occurring on zones assigned to this zone type. Enter the
codes sequentially (all 6 digits). When entering digits, [#] moves
cursor back, [] moves forward. Press [] when done to continue.
KEYPAD OPTIONS
(Options for keypad 1, address 16, are set by the factory and cannot be changed.)
NOTE: Each keypad must be assigned a unique address. Keypads
programmed with the same address will give unpredictable results.
190 Keypad 2 Device Address 17
[0] [0]
Enable: 0 = disabled; 1 = enabled Enable Sound
Sound: 0 = no suppression
1 = suppress arm/disarm and E/E beeps
2 = Suppress chime beeps only
3 = suppress arm/disarm, E/E, and chime beeps
Enable Sound
191 Keypad 3 Device Address 18
[0] [0]
192 Keypad 4 Device Address 19
[0] [0]
193 Keypad 5 Device Address 20
[0] [0]
194 Keypad 6 Device Address 21
[0] [0]
195 Keypad 7 Device Address 22
[0] [0]
196 Keypad 8 Device Address 23
[0] [0]
197 Exit Time Display Interval
[0]
0 = no display; 1-5 = seconds between display refresh
NOTE: If enabled and using only 2-digit fixed-word keypads (e.g.,
6150RF), do not set exit delay time greater than 96 seconds. See
Installation Instructions for explanation.
199 ECP Fail Display
[0]
0 = 3-digit display (1 + device address)
1 = 2-digit fixed-display as 91
Vista de pagina 4
1 2 3 4 5 6 7 8 9 10 ... 15 16

Comentarios a estos manuales

Sin comentarios