49 Split/Dual Reporting
[0]
0 = Standard/Backup reporting only (all to primary unless fail)
Primary Phone No. Secondary Phone No.
1 = Alarms, Restore, Cancel Others
2 = All except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All
4 = All except Open/Close, Test All
5 = All All
50 Burglary Dialer Delay
[2, 0]
Delay Time: Delay Time VISTA-10PSIA
0 = no delay UL: must be 0 Delay Disable
1 = 15 seconds; 2 = 30 seconds; 3 = 45 seconds
SIA Guidelines: delay must be minimum of 30 seconds
VISTA-10PSIA:
Delay Time: 1 = 15 seconds; 2 = 30 seconds; 3 = 45 seconds
Delay Disable:
0 = use delay set in entry 1
1 = dial delay disabled for zones listed in zone list 6 (use zone list 6
to enter those zones that require dial delay to be disabled;
these zones ignore the setting in entry 1)
UL: Dial delay plus entry delay must not exceed one minute; use zone
list 6 to disable dial delay from appropriate zones, if necessary.
53 SESCOA/Radionics Select [0]
0 = Radionics (0-9, B-F), and all formats other than SESCOA
1 = SESCOA (0-9 only reporting)
54 Dynamic Signaling Delay
[0]
Delay selectable from 0 to 225 secs in 15-sec increments.
0 = no delay (both signals sent); 1 = 15 secs; 2 = 30 secs, etc
UL: Grade AA must be 0; Grade A must be 15 max
55 Dynamic Signaling Priority
[0]
0 = Primary Dialer first; 1 = Long Range Radio first.
For UL Commercial Burglary installations that use a DACT and LRR,
this field must be 0.
56 -*58 Menu Modes (see page 2 for description)
PROGRAMMING SYSTEM STATUS, & RESTORE REPORT CODES (
59 -
68,
70 -
76, and
89):
For 3+1 or 4+1 Standard Format: Enter a code in the
first
box: 19, #+10 for
0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F.
A 0 (
not
#+10) in the
first
box will disable a report. A 0 (
not
#+10) in the
second
box will result in automatic advance to the next field.
For Expanded or 4+2 Format: Enter codes in
both
boxes (1st and 2nd digits)
for 19, 0, or BF, as described above.
A 0 (
not
#+10) in the
second
box will eliminate the expanded message for that
report. A 0 (
not
#+10) in
both
boxes will disable the report.
For Ademco Contact ID® Reporting: Enter any digit (other than 0) in the
first
box, to enable zone to report (entries in the
second
boxes are ignored).
A 0 (
not
#+10) in the
first
box disables the report.
UL: see installation instructions for requirements
SYSTEM STATUS REPORT CODES
59 Exit Error Report Code [0]
See box above for entries. VISTA-10PSIA: [1] Always enabled.
60 Trouble Report Code [00] |
61 Bypass Report Code [00] |
62 AC Loss Report Code [00] |
63 Low Bat Report Code [00] |
64 Test Report Code [00] |
Use Scheduling mode to set periodic test reports or use the following
key commands to set schedule 2 to the stated repeat option (first test
report sent 12 hours after command):
installer code +[#] + [0] + 0 = test report sent every 24 hours
installer code +[#] + [0] + 1 = test report sent once per week
installer code +[#] + [0] + 2 = test report sent every 28 days
65 Open Report Code [0]
66 Arm Away/Stay Rpt Code
[0,0]
Away Stay
67 RF Trans. Low Bat Report Code [00] |
UL: must be enabled if wireless devices are used
68 Cancel Report Code [00] |
VISTA-10PSIA: [10] Report enabled.
69 Recent Closing Report Code [11] |
VISTA-10PSIA: Always enabled. Field does not apply to other controls.
RESTORE REPORT CODES
70 Alarm Restore Rpt Code [0]
71 Trouble Restore Rpt Code [00] |
72 Bypass Restore Rpt Code [00] |
73 AC Restore Rpt Code [00] |
74 Low Bat Restore Rpt Code [00] |
75 RF Trans. Lo Bat Rst Rpt Code [00] |
UL: must be enabled if wireless devices are used
76 Test Restore Rpt Code [00] |
OUTPUT AND SYSTEM SETUP
77 Daylight Savings Time [4][10]
|
Start/End Month
0 = Disabled; 1-9 = January-September (1 = Jan, 2 = Feb, etc)
#+10 = October; #+11 = November; #+12 = December
78 Daylight Savings Time [1][5]
|
Start/End Weekend
0 = disabled, 1 = first, 2 = second, 3 = third
4 = fourth, 5 = last, 6 = next to last, 7 = third to last
79 -*82 Menu Modes (see page 2 for description)
84 Auto Stay Arm
[1]
0 = no, 1 = yes, auto stay arm enabled
85 Cross Zone Timer [0]
This option not for use in UL installations.
0 = 15 seconds 6 = 2-1/2 min #+12 = 8 min
1 = 30 seconds 7 = 3 min #+13 = 10 min
2 = 45 seconds 8 = 4 min #+14 = 12 min
3 = 60 seconds 9 = 5 min #+15 = 15 min
4 = 90 seconds #+10 = 6 min
5 = 2 minutes #+11 = 7 min
(assign cross zones on zone list 4, with *81 Menu mode)
86 Cancel Verify Keypad Display
[1]
0 = no, 1 = yes
87 Misc. Fault Delay Time [0]
(used with Configurable Zone Type digit 6)
0 = 15 seconds 6 = 2-1/2 min #+12 = 8 min
1 = 30 seconds 7 = 3 min #+13 = 10 min
2 = 45 seconds 8 = 4 min #+14 = 12 min
3 = 60 seconds 9 = 5 min #+15 = 15 min
4 = 90 seconds #+10 = 6 min
5 = 2 minutes #+11 = 7 min
UL: may only be used on non-burglar alarm/ non-fire alarm zones
when used in fire and/or UL burglar alarm installation
88 Program Mode Lockout Options
[0]
0 = standard *98 installer code lockout
(reentry only by [] + [#] within 50 seconds after power up)
1 = lockout [] + [#] reentry after *98 exit
2 = not used
3 = lockout local programming after *98 exit (reentry by downloader only)
89 Event Log Full Report Code
[00]
|
See box above *59 for report code entries.