Vista de pagina 9
alarm. A system-wide EEPROM dehned number of alarm
reports for this zone will be allowed 10 be transmitted (swinger
suppression) by the communicator untd an OFF sequence is
performed. The communicator will transmit a restoral message
when the zone is restored for a time greater than its physical
response time (less than 1 second).
Type 9. FIRE ZONE: Opens in this zone will result in “troubles”. Shorts
will result in alarms. Note: Zone 1 will support 2-wire Smoke
Detectors (using the EOL resistor configuration): Zones 2
through 8 can be used for heat detectors and pull stations and
for 4-wire Smoke Detectors with external (manual) power inter-
rupt; Zone 9 cannot be used for Fire.
Fire zones may not be bypassed. A fire zone m trouble will not
prevent the burglary system from being armed in any mode
A system-wide EEPROM defined number of alarm reports for
this zone will be allowed to be transmitted (swinger suppres-
sion) by the communicator in one armed period. The communi-
cator will transmit a restoral message when the zone
is restored (less than 1 second).
Type 10. INTERIOR DELAY ZONE: This type of zone will always have
an Entry delay #l and Exit delay HI. Thw zone IS not enabled
after armmg until termination of the (EEPROM defined) Exit
delay #1. If this zone E faulted, three beeps will be emitted by
the Control. If Code + OFF E not entered before termination of
the (EEPROM defined) Entry delay #1, an alarm will be mitlated.
A system-wide EEPROM defined number of alarm reports for
this zone WIII be allowed 10 be transmitted (swinger suppres-
sion) by the communicator in one armed period. The commun-
icator will transmit a restoral message when the zone IS re-
stored for a time greater than its physical response time (less
than 1 second).
During the disarmed state, a faulted contact WIIIresult m NOT
READY being displayed. Subsequent depression of the READY
key will cause all the faulted zones to be sequentially displayed,
but no commurucator reports will be initiated.