Examples (Ademco High Speed Zone format)
4. After transmission of Example 3, subscriber #0135 sends a closing:
1. At subscriber #5890, channels 2 and 5 go into alarm (and initiate a Subscriber Channel Number
call) and channel 6, which has previously reported an alarm is still
Identification
1234 5676 9
triggered.
Message:
0135 D444 4444 4
Subscriber
Channel Number
Identification 1234 5678 9
Message: 5890
5155 1655 7
5
2
Channel 2: NEW ALARM
Channel 5: NEW ALARM
Channel 6: PREVIOUSLY REPORTED ALARM
(still in effect)
Still at subscriber #5890, following the events of example 1 above,
channel 2 restores (initiating the ~all) and channels 5 and 6 remain in
alarm
6
Subscriber Channel Number
Identification 1234 5676 9
Message”
5890
5355 6655 7
Channel 2:
NEW RESTORE
Channels 5,6: PREVIOUSLY REPORTED ALARMS
(still In effect)
Channel 1: USER ID - User#13 (= hex D) closed
Channels 2-9: CLOSING REPORT TRANSMITTED
Subscriber #01 35 sends a duress message:
Subscriber
Channel Number
Identification
1234 5676 9
0135
1555 5555 1
Channel 1: DURESS REPORT
Channel 9: SUPPLEMENTAL ALARM ZONES
TRANSMITTED
Subscriber #01 35 User #7 bypasses faulted zone 2 (for the sake of
this example, Zone 2 = Channel 3, not a requisite) and then arms the
system.
Subscriber Channel Number
Identification 1234 5676 9
Message: 0135
0135
5515 5555 3 (Bypass Report)
7444 4444 4 (Closing Report)
3. Subscriber #0135 sends an opening:
Bypass restorals are transmitted when the restoral takes place
Subscriber
Channel Number
0135 5535 5555 3
Identification
1234 5678 9
Message: 0135
1222 2222 2
Channel 1.
USER ID User #l opened
Channels 2-9: OPENING REPORT TRANSMITTED