FUNCTION
ALARM COUNT
TEST REPORT
INITIATION TIME
ADDRESS
*82
*83
ADEMCO HIGH SPEED
84
FORMAT USED ON
WATS LINES
DO NOT USE ’85
ZONE EXPANDER
*86
TYPE SELECTION
o
COMMENTS: Enter 01-15.
This option limits the number of messages Alarms or Troubles) sent for a specific channel in an
armed period (Swinger Suppression) before additional reports from that channel are inhibited. This
selection is system-wide.
n
COMMENTS: Enter the time in hours from the time that the programming mode is exited that the
first test report shall be transmitted. 00 entry signifies immediately upon exiting. 01-31 represents
the range in hours that can be selected,
COMMENTS: Enter 1 if Ademco High Speed Format (either traditional or 4+2 versions) will be
transmitted on 800/WATS lines where satellite links may be used. Enter O if other formats are
selected or if local telco lines are being used.
•1
0 MUST BE ZERO
COMMENTS: This field is otherwise used for subzone control enable. It is recommended that a
4130NI be used to perform that function instead, for monetary savings.
COMMENTS: Enter 1 if No. 4208 Eight Zone Expander is being used. Enter O if other VECTOR type
RPMs are being used to expand the number of zones. Imporianti See the section on an earlier page
entftled “Zone Expansion” for proper configuration of the No. 4208.