FUNCTION
ADDRESS
4+2 EXPANDED
*81
FORMAT NON-ALARM
CODES (CONT’D)
“close” E desired on Ademco No. 685 Recewer or if closlng by
user is to be processed on an Ademco AutomatIon System
● 1st digit of Open Report must be B (hex 11 ) if English printout of
“open” is desired on Ademco No. 685 Receiver or if opemng by
user is to be processed on an Ademco Automation System.
● The 2nd digit of both the Close and Open Reports represents
the user ID for the Installation Company Security Code. User
No. 2 is automatically assigned an ID one higher than this code
(e.g., if 01 is keyed, User 2 reports as 2, User 3 as 3, etc...)
❑ o
❑ o
Izn
❑ ln
❑ o
cm
Em
Em
❑ 0
❑
0
POWER UP REPORT (1st digit)
POWER UP/DOWNLOAD
ATTEMPT REPORT CODES (2nd digit)
AC LOSS REPORT (1St dglt)
AC LOSS REPORT (2nd digit)
AC RESTORE REPORT (1st digit)
AC RESTORE REPORT
(2nd digit)
Not used -
Zeroes to be Entered
Not used -
Zeroes to be Entered
CANCEL REPORT (1st dig[t)
CANCEL REPORT (2nd digit)
COMMENTS:
● Power Up E transmitted after a power reset or after exiting the
Program Mode.
o Cancel is transmitted if system is shut down while a burglary
alarm is sounding.
. Enter all reporting codes as double digits (see Address *65).
Disable = 00 (no code reporting) if both 1st and 2nd digits are
so programmed
Comentarios a estos manuales