Zone expansion to an additional 8 zones is achieved by first Installing the
optional No. 41 52LM Loop Module onto the No. 4171 XT (after [t has been
installed). The No. 4152LM can then be connected to a No. 4208 Eight
Zone &pander by a single pair of w!res providing both power and signal-
ing. Path of the 8 zones on the No. 4208 can be programmed from the
various types described in this manual that are available for use on the
basic.9 zones, wdh one exception. There IS no ability to support 2 wire
smoke detectors on any of the zones available in the No. 4208 Zone
Expander The No. 4208 Zone Expander may be located near the No.
4130XT or remotely from )t. The two wire run to it should utihze twisted
pair wiring and should not be run in,close proximity to profected pre-
mises intercom wiring [at least a 3-inch (8 cm) separation]. For the max-
imum wiring run permissible to the zone expander for various wiring
gauges, see the Specifications Section relatwe to the No. 4208 Zone
Expander later in this manual.
IMPORTANT In order to utilize the No 4208 to obtain zones 10-17, that
product’s DIP switches must be set as follows:
2 3
4
5
ON ON ON OFF
noun
(as If set for sensor numbers 113-120, as cited in the instructions for the
No 4208)
Installation instructions for the No 4152LM and wiring connections to the
No, 4208 are provided m a subsequent secllon entitled “INSTALLATION
OF
No. 4152LM AND WIRING TO No. 4208”.
Installer Code:
The installer programs the Installer Code initially as part of the program-
ming procedure (see “Programming the Security Control”) In this system,
the installer is considered to be user #1 The installer code permits re-entry
into the programming mode (unless *98 has been previously used to exit
the programming mode or if user #1 was not enabled in Address *52) and
also allows access to the normal functions of the system. During initial
programming, the installer also programs the Master security code into the
system
Installer Code (User #l ), assigned during
programming.
Installer exits programming mode with:
*99 (allows re-entry into programming mode with installer code).
or
X98 (does not allow re-entry to programming mode unless system is
first powered down and then repowered). Installer code IS dis-
abled whemthis exlf is used
Master Security Code
The Master security code can be used to assign up to thirteen secondary
codes (to users #3-#1 5); it can also be used to remove all secondary
codes from the system (individually). The person to whom the Master
Vista de pagina 11