The VISTA 4130XT IS a microprocessor-based security control which
provides up to 9 wired zones in the basic product, with expansion to an
additional wired zones when connected toa2-wire zone expansion bus
driven bytheoptional No.4152LM Loop Module Thesecurity control is
housed in a wall-mounled plastlc enclosure measurmg only 8.4” (21.3
cm) wide x 4.75 (12 cm) high x 1.1” (2.8 cm) deep, and is equipped with
a multifunction 12-key digital keypad, a multipurpose LCD English lan-
guage display and a built-in 85 db piezoelectric sounder that meets UL
requirements as an alarm sounder (an external sounder IS therefore
optional). ConnectIons to the security ,control are made via a 24-pm plug-
in connector equipped with flylng leads which interface to the wired
loops, plug-in DC Power Pack, back-up battery, optional external alarm
sounder, etc.
The security control is programmable from its own keypad or from a
4137 or 4157 remote console (optional), and can also be programmed
locally from the 699 Programmer (using a 695-30XT cartridge).
Programmed options to eslablish specific alarm and reporting features
are stored in electrically erasable, non-volatile EEPROM memory. This
means that the unit can be reprogrammed many times (unlike umts
equipped with PROMS) and that information which has been
programmed will not be lost in the event of a complete loss of power. For
installer convenience, the control is factory-programmed to a set of
values that is designed to meet the needs of many installations. However,
these can be altered by the installer to suit the specific needs of a
particular installation or installation company, following the instructions
provided in the programming section of this manual (factory-programmed
values are also shown in this section).
A plug-in Communication Interface board (4171 XT) is required with this
system and provides communication capability (central station reporting,
etc,) over existing telephone lines as well as zone expansion
connections.
An optional, economical, remote keypad (4131 or 4147) can be used for
arming, dmarmmg, etc., from a remote indoor location within the pro-
tected premises, This unit is a compact 12-button keypad with two sys-
iem status indicators (LEDs) and a built-in p!ezoelectric sounder that
provides warning and alarm sounds. Requires a 10-wire connecbon to
the control.
An optional remote console (41 57) will provide system status indications
and WIIIperm[t virtually all system control functions from its keypad. The
console will also provide visible and audible indications of troubles and
alarms by means of LEDs and numeric (zone number) display and bullt-
In piezoelectric sounder. Requires only a 4-wire connection to the
control
An optional remote console (41 37) is available which is identical to the
4130XT control in Its appearance, system operation, LCD displays, and
loud piezoelectric alarm sounder. Requires only a 4-wire connection to
the mam control.
A complete list of optional accessories will be found m a section toward
the end of this manual under the heading “Optional Accessories” (see
Index).
Zone Characteristics
Zone 1:
zones 2-a
Zone 9
Programmable Zone, may be used as EOLR superwsed Fire
Zone (supports 2-wire Smoke Detectors), or may be used as
a non-fire zone with N C contacts only, 350-500 msec
response.
Programmable Zones, EOLR supervised, 350-500 msec
response
Programmable Zone, NC. contacts only, fast 10-15 msec
response.