FUNCTION ADDRESS
OPE?i/CLOSE
*39
REPORTING ENABLE
BY USER CODE
REPORTING CODE
*4O
FOR ATTEMPT
(SUCCESSFUL OR UN-
SUCCESSFUL) BY A
REMOTE AGENCY TO
GET INTO A DOWN-
LOAD MODE WITH
THE SYSTEM OR FOR
SOMEONE TO
LOCALLY CHANGE
THE PROGRAM
DISABLE USAGE OF *41
END-OF-LINE
RESISTOR SUPER-
VISION ON WIRED
ZONES 2-8
DIAL TONE PAUSE
*42
9 10 11 12 13 14 15
❑ nnnnnn
COMMENTS: Enter O (disable) or 1 (enable). Determines which user codes will send open/close reports
❑ o
LOCAL REPROGRAM/DOWNLOAD ATTEMPT REPORT (1st digit)
COMMENTS: Applicable if downloading will be utilized or not. Enter reporting code as double digits. Disable= 00
(no code reporting).
01=1
06=6 11=6
02=2 07=7 12=C
03=3 08=8 13=D
04=4 09=9 14=E
05=5 10=0 15=F
Note: If 4+2 by point reporting E being used, the second digit is the second digit of the power up code
❑
COMMENTS. Enter 1 to change zones 2-8 to N.C. loops that detect only an “open” and do not require end-of-line
resistors (EOLRS) Enter O to retain EOLR supervision of zones 2-8.
❑
COMMENTS: This feature determines the wait time for dial tone detection before diallng will commence If detec
tion does not take place.
Enter single digit, O (5 seconds),
1 (11 seconds) or 2 (30 seconds.)
.——... —