ADEMCO Vista-32FB Guía de usuario

Busca en linea o descarga Guía de usuario para Los Sistemas De Control De Acceso De Seguridad ADEMCO Vista-32FB. ADEMCO Vista-32FB User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 72
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
K3522V2 6/04 Rev A
$
$
'
'
(
(
0
0
&
&
2
2
9
9
,
,
6
6
7
7
$
$
6
6
(
(
5
5
,
,
(
(
6
6
9
9
,
,
6
6
7
7
$
$
)
)
%
%
9
9
,
,
6
6
7
7
$
$
)
)
%
%
&RPPHUFLDO)LUHDQG%XUJODU\
3DUWLWLRQHG6HFXULW\6\VWHP
:LWK6FKHGXOLQJ
8VHU*XLGH
Vista de pagina 0
1 2 3 4 5 6 ... 71 72

Indice de contenidos

Pagina 1 - 8VHU*XLGH

K3522V2 6/04 Rev A $$''((00&&2299,,6677$$66((55,,((6699,,6677$$))%%99,,6677$$))%%&RPPHUFLDO)LUHDQG

Pagina 2

– 10 – About The Keypads General IMPORTANT: If the keypad beeps rapidly upon entering the premises, it indicates that an alarm has occurred during y

Pagina 3 - TABLE OF CONTENTS

– 11 – Functions Of The Keypad 1OFF4MAX7INSTANTREADY2AWAY5TEST8CODE03STAY6BYPASS9CHIME#SUPERTROUBLEARMEDREADY6160CR-003-V1SPEAKERLCDDISPLAYLEDSFUNCT

Pagina 4

– 12 – Functions Of The Keypad (cont’d)ALPHA DISPLAY WINDOW: A 2-line, 32-character Liquid Crystal Display (LCD). Displays protection point identif

Pagina 5 - System Overview

–13 – Functions Of The Keypad (cont’d) ✳ READY : When depressed prior to arming the system, the keypad will display all open protection zones wi

Pagina 6 - System Overview (cont’d)

– 14 – Entry/Exit Delays General Information Your system has installer-programmed time delays, known as exit delay and entry delay. Whenever you arm

Pagina 7

–15 – Security Codes & Authority Levels General Information At the time of installation, you were assigned an authority level and a personal fou

Pagina 8

– 16 – Security Codes & Authority Levels (cont’d) Authority Levels Authority levels define the system functions a particular user can perform. D

Pagina 9

–17 – Security Codes & Authority Levels (cont’d) General Rules on Authority Levels and Changes • A user may not delete or change the user code

Pagina 10 - About The Keypads

– 18 – Security Codes & Authority Levels (cont’d) To Add a User IMPORTANT: Temporary users should not be shown how to use any system function th

Pagina 11 - Functions Of The Keypad

–19 – Security Codes & Authority Levels (cont’d) MULTI-ACCESS ? 0 = NO , 1 = YES If you as a user have access to other partitions, the keypad wi

Pagina 12

– 2 –

Pagina 13

– 20 – Security Codes & Authority Levels (cont’d) To Change a User’s Code CODE 1. Enter Master or Manager code and press the 8 key +

Pagina 14 - Entry/Exit Delays

–21 – Accessing Other Partitions To Access Another Partition Each keypad is assigned a default partition for display purposes, and will show only th

Pagina 15 - Quick Arming

– 22 – Accessing Other Partitions (cont’d) Global Arming Notes: • When performing a Global Arm, if there are faults in any of the selected partitio

Pagina 16 - Authority Levels

–23 – Accessing Other Partitions (cont’d) The following is an example of what would be displayed for a fault condition on Zone 002 (Loading Dock Win

Pagina 17 - To Exit User Edit Mode

– 24 – Accessing Other Partitions (cont’d) Common Lobby Operation When an installation consists of a partition that is shared by users of other part

Pagina 18 - To Add a User

–25 – Accessing Other Partitions (cont’d) How User Codes Affect the Common Lobby Codes with “Global” Arming If your code is given global arming when

Pagina 19

– 26 – Checking For Open Zones Using the ✴ READY Key Before arming your system, all protected doors, windows and other protection zones must be c

Pagina 20 - To Delete a User

–27 – Displaying All Zone Descriptors Using the ✳ READY Key The Alpha Keypads can also display all the zone descriptors that are programmed in yo

Pagina 21 - Accessing Other Partitions

– 28 – Bypassing Protection Zones Using the 6 BYPASS Key This key is used when you want to arm your system with one or more zones intentionally

Pagina 22 - Master Keypad Operation

–29 – Bypassing Protection Zones (cont’d) Quick Bypass Your system allows you to easily bypass all open (faulted) zones without having to enter zone

Pagina 23

– 3 – TABLE OF CONTENTS SYSTEM OVERVIEW ...5 General ...5 A Partitioned

Pagina 24 - Common Lobby Operation

– 30 – Arming Perimeter Only (With Entry Delay ON) Using the 3 STAY key Use this key when you are staying home, but might expect someone to use

Pagina 25

–31 – Arming Perimeter Only (With Entry Delay OFF) Using the 7 INSTANT Key Use this key when you are staying home and do not expect anyone to us

Pagina 26 - Checking For Open Zones

– 32 – Arming All Protection (With Entry Delay ON) Using the 2 AWAY Key Use this key when no one will be staying on the premises. When armed in

Pagina 27 - Using the ✳ READY Key

–33 – Arming All Protection (With Entry Delay OFF) Using the 4 MAXIMUM Key Use this key when the premises will be vacant for extended periods of

Pagina 28 - Bypassing Protection Zones

– 34 – Disarming And Silencing Alarms Using the 1 OFF Key The OFF key is used to disarm the system and to silence alarm and trouble sounds. See

Pagina 29 - Displaying Bypassed Zones

–35 – Using The Keyswitch General Your system may be equipped with a keyswitch for use when arming and disarming a partition. A red and green light

Pagina 30 - Arming Perimeter Only

– 36 – Chime Mode Using the 9 Key Your system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME mod

Pagina 31

–37 – Viewing Alarm Company Messages General Information Users of the system may periodically receive messages on their display screens from their m

Pagina 32 - Arming All Protection

– 38 – Panic Keys (For Manually Activating Silent And/Or Audible Alarms) Using Panic Keys Your system may have been programmed to use special key co

Pagina 33

– 39 – Speed Key (Macros) General Information The “A”, “B”, “C”, and/or “D” keys can be used to activate a string of commands up to 32 keystrokes

Pagina 34 - Memory of Alarm

– 4 – PANIC KEYS... 38 Using Panic Keys ...38 SPEED KEY (MACROS)...

Pagina 35 - Using The Keyswitch

– 40 – Speed Key (Macros) (cont’d) Executing To execute a Speed Key sequence, do the following: If a lettered key, A-B-C, has been assigned as a Spe

Pagina 36 - Chime Mode

– 41 – Access Door Control General Information Your system may be set up such that a locked access door (such as in a lobby) can be unlocked momenta

Pagina 37

– 42 – Using #70 Relay Menu Mode General Information Your system may be set up so that certain lights or other devices can be turned on or off by us

Pagina 38 - Panic Keys

– 43 – Using Schedules Delaying the Closing Time Your system’s programmed schedules may automatically arm the system at a predetermined time. In the

Pagina 39 - Speed Key (Macros)

– 44 – Using Schedules (cont’d) Programming Temporary Schedules Temporary schedules only affect the partition from which it is entered. Temporary sc

Pagina 40 - Speed Key (Macros) (cont’d)

– 45 – Using Schedules (cont’d) DAYS ? MTWTFSS HIT 0-7 X X This is the prompt that actually activates the temporary schedule, and allows the te

Pagina 41 - Access Door Control

– 46 – Programming Device Timers General Information Device timers consist of an ON time & an OFF time, and selected days of the week in which t

Pagina 42 - Using #70 Relay Menu Mode

– 47 – Programming Device Timers (cont’d) 00 ON TIME ? 00:00 PM Enter the time you want the device turned on using 00:01 - 11:59 format. When the d

Pagina 43 - Using Schedules

– 48 – Using #77 Instant Activation Mode The #77 Instant Activation Mode is used to activate outputs, bypass zones, etc. immediately upon exiting th

Pagina 44 - Using Schedules (cont’d)

– 49 – Using #77 Instant Activation Mode (cont’d) Bypass Commands Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for

Pagina 45

– 5 – System Overview General Your Honeywell security system consists of a main control panel, at least one keypad, and various sensors strategicall

Pagina 46 - Programming Device Timers

– 50 – Using #77 Instant Activation Mode (cont’d) Additional Commands Action Code Action Specifier 77 Access Point Group Enable Group # 78 Access

Pagina 47

– 51 – Event Log Procedures General Information The system has the ability to record various events in a history log wherein each event is recorded

Pagina 48

– 52 – Event Logging Procedures (continued) 4. Use the [3] & [1] keys (for next and previous categories respectively) to display the categories

Pagina 49

– 53 – Testing The System (To Be Conducted Weekly) Using the 5 TEST Key The TEST key puts your system into Test mode, which allows each protecti

Pagina 50

– 54 – Fire Alarm System Your fire alarm system (if installed) is on 24 hours a day, providing continuous protection. In the event of an emergency,

Pagina 51 - Event Log Procedures

– 55 – Fire Alarm System (cont’d) Fire Display Lock If several zones produce an alarm before any are silenced, the system can be programmed to lock

Pagina 52 - 4] at any time

– 56 – Trouble Conditions Typical Trouble Displays The word CHECK or TRBL on the Keypad’s display, accompanied by a rapid "beeping" at the

Pagina 53 - Testing Your System

– 57 – Trouble Conditions (cont’d) • A display of "COMM. FAILURE" at the Keypad indicates that a failure has occurred in the telephone co

Pagina 54 - Fire Alarm System

– 58 – Emergency Evacuation Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the Natio

Pagina 55 - Fire Alarm System (cont’d)

– 59 – Maintaining Your System Taking Care of Your System The components of your security system are designed to be as free of maintenance as possib

Pagina 56 - Trouble Conditions

– 6 – System Overview (cont’d) A Partitioned System Simply stated, a partitioned system shares one physical alarm system among different users, each

Pagina 57 - Trouble Conditions (cont’d)

– 60 – Maintaining Your System (cont’d) Silencing Low Battery Warning Tones at the Keypad The keypad’s warning tones can be silenced by performing a

Pagina 58 - Emergency Evacuation

– 61 – Quick Guide To System Functions FUNCTION PROCEDURE COMMENTS Check Zones Press [✱]. To view faulted zones when is system not ready Display

Pagina 59 - Maintaining Your System

– 62 – Quick Guide To System Functions (cont’d) FUNCTION PROCEDURE COMMENTS Delete a User Enter master/manager code. Press CODE [8]. Enter user n

Pagina 60 - Routine Care

– 63 – Summary Of Audible Notification (Alpha Display Keypads) SOUND CAUSE DISPLAY LOUD, INTERRUPTED* Keypad & External FIRE ALARM FIRE is d

Pagina 61

– 64 – UL NOTICE: This is a “GRADE A” system. “FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT” This equipment has been tested to FCC req

Pagina 62

– 65 – “FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 NOTICE This equipment complies with Part 68 of the FCC rules. On the front cover of this e

Pagina 63 - (Alpha Display Keypads)

– 66 – CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT NOTICE The Canadian Department of Communications label identifies certified equipment

Pagina 64

– 67 – WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protect

Pagina 65

– 68 – Index #70 command ... 42 4285 or 4286 VIP module ... 9, 42 AC Loss ...

Pagina 66

– 69 – Memory of Alarm...7, 34 Messages...37 Modem Comm...

Pagina 67 - WARNING!

– 7 – System Overview (cont’d) Burglary Protection The burglary protection portion of your system must be turned on or "armed" before it w

Pagina 68

– 70 – LIMITED WARRANTY Honeywell International Inc., 165 Eileen Way, Syosset, New York 11791, warrants its product(s) to be in conformance with it

Pagina 69

– 71 –

Pagina 70 - LIMITED WARRANTY

¬.9'lK3522V2 6/04 Rev A 165 Eileen Way, Syosset, New York 11791Copyright © 2004 Honeywell International, Inc.www.honeywel

Pagina 71

– 8 – System Overview (cont’d) Speed Key (Macros) The system can store a string of up to 32 keystrokes, which can be activated anytime by simply pre

Pagina 72 - ¬.9'l

– 9 – System Overview (cont’d) Master Keypad Operation A "Master" keypad is one on which the status of all 8 partitions is displayed simul

Comentarios a estos manuales