ADDRESSFUNCTION
ENTRY DELAY #2
EXIT DELAY #2
ALARM SOUNDER
DURATION
ALARM SOUNDER
SELECTION
KEYSWITCH ARMI
DISARM ENABLE
*11
*12
“13
●14
●15
❑ o
COMMENTS: Defines the time period between a fault occurring [n a zone to which Entry Delay #2 has been
assigned and the time when the alarm will sound, (UL 1023 Household Burglary usage permits a maximum of 45
seconds,) Must be set for longer pariod than Entry Delay #1 (in Address *09).
Enter 00-15. Multiply by 15 seconds to determine time delay (O-225 seconds available).
Em
COMMENTS: Defines the time delay period after the system arming code is keyed when zone to which this delay
has been assigned will arm. (UL 1023 Household Burglary usage permits a maximum of 60 seconds).
Must be set for longer period than Exit Delay #1 (in Address *1 O).
Enter 00-15. Multiply by 15 seconds to determine time delay (O-225 seconds available).
❑ l
COMMENTS: Defines the length of time an external or the control’s alarm sounder will sound on all audible alarms
(UL 1023 Household Burglary usage requires a minimum of 4 minutes).
Enter 01-15. Multiply by 2 minutes to determine sounder duration.
❑
COMMENTS: Enter O for use with Ademco 740 or BRK BK-PA400B piezoelectric sounder, or AMSECO MSB-1 OG
or ABB-1 031 12V Motor Bell or for external relay activation. Do not enter “l”.
•1
COMMENTS: Requires the use of zone 7 wired loop (zone 7 no longer available as protection zone when used for
keyswitch operation).
Enter
1for keyswitch enabl~ otherwise, enter O. NOTE: 10 must have been entered for Zone 7 in Address ’02.
Reports opening/closing by user #7 if reporting is enabled in Address ’52.