INSTALLATION INSTRUCTIONSViSTASECURITY SYSTEMNo. 4130XT10/88Previous Menu
alarm. A system-wide EEPROM dehned number of alarmreports for this zone will be allowed 10 be transmitted (swingersuppression) by the communicator unt
TABLE A. ZONE ASSIGNMENTSA zone type must be assigned to each physical zone m use For convenience, the following chart has been provided for checking
Zone expansion to an additional 8 zones is achieved by first Installing theoptional No. 41 52LM Loop Module onto the No. 4171 XT (after [t has beenins
code IS assigned IS considered to be user #2. In some apphcations(commercial installations for example), user #2 (with Master code) WNbe the main user
APPLICATION 1,MASTER SECURITY CODEMAIN USER“Clnclcl”,er,,ICAN ASSIGN TEMPORARY CODES TO: IiNote: All codes can Arm/Disarm the System*User #3 can assig
APPLICATION 2SECONDARYSECURITY CODE❑ 000User #15BUILDING MANAGER, ETC.MASTER SECURITY CODE(User #2)-0000 user,,CAN ASSIGN SECOfiDARY CODES TO 11r1BUIL
(See Diagram 1, Summary of Connections)A 24-pin plug-in connector with flying leads is provided to interface the4130XT to the wired loops, the externa
LJhii?.,”. ,“ ,..,.%,... . . ,X4,“+—. . ,,0. . .UN ,.!7 . . . .. . ...7 ,,. ”.,.,,,..,” ,“”, !”..,,I +%’” !=%.==kn.-ii!g.I---------OPTlONAL4140RELAYMO
Remote Keyswitch Operation & WiringTABISEENOTEBELOWAn optional Remote Keyswitch may be used for remote arming and dis-arming (this is an installer
(SA4131-1O)REMOTEKEYPADCONNECTORl-?=CONNECTSTOREMOTEKEYPADINTERFACEONCONTROL{SEEDIAG1)QE8L!JEGREENREO[REDTo,LY\NGLEADSON 10.PINREMOTE BLUEKEYP4DCONNEC
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The optional Digital Communlcatlon Interface Board IS attached to therear of the Control as follows (refer also to Diagram 4).1234Remove the back cove
The optional No. 4152LM Loop Module is installed onto the No4171XTb. Secure the No. 4152LM by means of 3 srews (supplied).Digital Communications Inter
There are three methods that may be used for mounting the 4130XTControl, as follows:1, Surface Mounting: This type of mounting IS possible only when a
DIGITAL COMMUNICATIONBOARD IINSTALLED)lBPINGROUND STARTREMOTE KEYPADPHONE LINE (TIP)CONNECTORSTRAIGHT1INCOMING(IF USEOI10 PIN—PHONE LINE IRING)MA LE.T
INSERT NAMEPLATEINTO RECESSEDAREA (COVERSSCREW)/“1 // \ /L~(@bOARMED OPOWER~—SECURINGSCREWIFlush Wall Mounting:If a “rough-in” ring (41 33) has been p
insert the battery into the box, and make connections to its terminalsas follows, using the two 12-inch (30 cm) Red and Blackheads(equipped with FAST-
Refer to Diagram 9 for Steps 8,9 and 108. Mount the Control as follows. Insert securing screw (previouslyremoved) in screw hole at front of Control (s
METAL CLIPSPRING (NOTEEND)ASHEETROCKBIF SHEETROCK IS TOO THICK,BREAK OFF THE SCORED WINGNOTE :4-5/16’’(11 cm)H X 7-3/4’’(2Ocm) WWALL OPENING }S REQUIR
Installer options are stored in non-removable, electrically erasable, non-volatile EEPROM memory. These options must be programmed for theparticular i
EXIT PROGRAM-MING MODE:ADVANCE TO FIELD:PROGRAM FIELD:ERASE FIELDS:READ FIELD:RESTORE FACTORYPROGRAM SETTINGSSPECIAL MESSAGES*99 (always allows re-ent
4137 Remote Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AddressFunctionFactory Programmed ValueAddress Function00cINSTALLER CODE 401rMASTER SECURllY 1CODE02ASSIGNEZ1 oRESPONSETYPE FORZONES 1-8EZ2 oE23 ()E24
Address0506FunctionFactorycoASSIGNr10RESPONSElYPE FORc20VARIOUSKEYPAD PANICSAND ZONEE3~EXPANDER WIRINGSUPERVISIONE40%ogrammed ValueElo❑o❑o❑oElo❑oElo❑o
Address21222324252627282930313233FunctionFactory Programmed ValueDISABLE FIRETIME-OUTFIRE INDICATIONON DISPLAYMULTIPLE ALARMSTAMPER DETECT-ION DISABLE
Address3940414243444546474849Function Factory Programmed VaiueOPEN/CLOSEREPORTINGENABLE BYUSER CODEREPROGRAM/DOWNLOADATTEMPT REPORTEOLR DISABLE(Zones
AddressFunctionFactory Programmed Value61CHANNELASSIGNED TO,mmZeroes for zonesEACH ZONEcode reported)62,EIEIJIIEI,EIEI,EIEI6~~Sm,EilmAddressFunctionl-
Address FunctionFactory Programmed Value64 CHANNELSASSIGNED TODURESS ANDVARIOUS KEYPADPANICS65ALARM REPORT-ING CODESASSIGNED TOEACH CHANNELTim‘Em‘Em‘E
Address676869707172FunctionFactory Programmed ValueNON-ALARMCODES❑ H ,.,..,,,All zeroes (no codesNON-ALARM❑ m repo,e,)All zeroes (no codesCODES (CONT’
Address Function75 4 + 2 EXPANDEDFORMAT KEYPADPANICS/ZONE76Factory Programmed ValueAddressEXPANDER WIRING m—SUPERVISORYEVENT DIGIT(1st digit)4 + 2 E)(
Address Function Factory Programmed Value7879•14 + 2 EXPANDED 17 0FORMAT ZONE17 ID DIGIT❑o(2nd digit)❑o❑oElo•1o❑oEloIIo4 + 2 EXPANDEDHnFORMAT KEYPADPA
Address Function814 + 2 EXpANDEDFORMAT NON-ALARM CODES(CONTINUED)82ALARM COUNTAddress83848586FunctionFactory Programmed ValueTEST REPORTINITIATION TIM
The VISTA 4130XT IS a microprocessor-based security control whichprovides up to 9 wired zones in the basic product, with expansion to anadditional wir
SPECIFIC ADDRESS PROGRAMMING INSTRUCTIONSFUNCTIONADDRESSINSTALLER CODEMASTER SECURITYCODEASSIGN RESPONSETYPES FOR ZONES1-8*OO❑ nnnCOMMENTS: This 4-dig
FUNCTIONADDRESSFUNCTIONADDRESSASSIGN RESPONSETYPES FOR ZONES9-16ASSIGN RESPONSETYPE FOR ZONE 17*O3lUUZone92UUZonelCl3Cln Zonell4❑ 0 Zcme125UUZcme13fjU
FUNCTIONADDRESSDESIGNATE RIGHTZONE USAGENOT USEDENTRY DELAY #1EXIT DELAY #1*06*Q7*o6*Q9*1Q10 11 12 13 14 15 16❑ lnmlmlzoneslo-1617•1Zone 17COMMENTS: A
ADDRESSFUNCTIONENTRY DELAY #2EXIT DELAY #2ALARM SOUNDERDURATIONALARM SOUNDERSELECTIONKEYSWITCH ARMIDISARM ENABLE*11*12“13●14●15❑ oCOMMENTS: Defines th
FUNCTIONADDRESSCONFIRMATION OF●I6ARMING OINGENABLEAC POWER LOSS●17SOUNOINGNOT USED’18CONTROL ALARM●19SOUNDER DISABLENOT USED*2ODISABLE FIRE●2ITIME-OUT
FUNCTIONADDRESSMULTIPLE ALARMS●23DISABLE TAMPER*24DETECTION INEXPANSION ZONES10-17DISABLE DURESS●25REPORTING INADEMCO HIGHSPEED FORMATINTERNAL ALARM “
FUNCTIONADDRESSPOWER UP IN●28PREVIOUS STATEQUICK ARM●29TOUCH-TONE OR●3OROTARY DIALPABX ACCESS CODE*31❑COMMENTS: If selected (YES), on power-up the sys
FUNCTIONADDRESSSUBSCRIBER*32ACCT. NO.PRIMARY PHONENo. *33SECONDARYPHONEhJo.CENTRAL STATIONDOWNLOAD PHONENo.CENTRAL STATIONID NUMBER*34*35*36NUMBERENTE
FUNCTION ADDRESSDOWNLOAD*37COMMAND ENABLESINHIBIT BYPASS●3SOF ZONE1❑Dialer Shutdown2❑System Shutdown3 •10 Not Used4❑Remote Bypass5❑Remote Disarm6❑Remo
FUNCTION ADDRESSOPE?i/CLOSE*39REPORTING ENABLEBY USER CODEREPORTING CODE*4OFOR ATTEMPT(SUCCESSFUL OR UN-SUCCESSFUL) BY AREMOTE AGENCY TOGET INTO A DOW
Back-up 12V DC BatteryDC Power PackMounted externally. A spectal backbox (4132) is available for mountingPlug-in Power Pack (DC power converter). Plug
FUNCTIONDIAL TONEDETECTIONADDRESS*43RING DETECTION*44COUNTPRIMARY ACK WAIT *45PRIMARY*46TRANSMISSIONFORMATSECONDARY ACK*47WAIT❑COMMENTS: Determines wh
FUNCTION ADDRESSSECONDARY*48TRANSMISSIONFORMATSINGLE MESSAGE*49TRANSMISSION WITHCHECKSUMVERIFICATIONSESCOA/RADIONICS *5OSELECTIONDUAL REPORTING*51OPEN
FUNCTION ADDRESS4+2ZONE (MAX. OF*5317 WIRED ZONES)EXPANDED FORMATSELECTION4+2 ZONE (MAX. OF 9*54WIRED ZONES)FORMAT SELECTIONnCOMMENTS: Enter 1 if 4+2
The following reports (Addresses *55 - * 60) may be designated to raport aither in Standard or Expanded format. in aii cases, the Standardmessage repo
Ademco High Speed FormatThis format is the fastest format used in the alarm industryin that alarminformation on 8 zones can be received at a Central S
Examples (Ademco High Speed Zone format)4. After transmission of Example 3, subscriber #0135 sends a closing:1. At subscriber #5890, channels 2 and 5
7. If a trouble condition occurs in Zone 4 for subscriber #5890 and Zone4 was assigned 10 Channel 2, a trouble report is transmitted.SubscriberChannel
FUNCTIONRESTOREADDRESSREPORT*56❑COMMENTS: Enter O (Standard Report) or 1 (Expanded Report).When a zone of protection alarm, bypass or trouble report i
FUNCTIONADDRESSLOW BATTERY,*6OAC LOSS ANDTEST REPORTCHANNEL ASSIGNED *61TO EACH ZONENOTE: Channel 9 (09) is reservedfor duress reporting when thatfunc
FUNCTIONADDRESSCHANNEL ASSIGNED *63100 Zone17TO EACH ZONE(CONT’D)2 •~ Not”,,,3 •~ Not Used5 •~ Not usedaEIEIN.tusedCOMMENTS: Enter all channel IDsas d
Commanding:There are two types ot commands that can be issued to the system:1. Control Commands —- To Arm the System in the Away Mode* (’)- To Disarm
FUNCTIONADDRESSALARM REPORTING*65,00CODES ASSIGNEDTO EACH CHANNEL2003CICI4CICI5CICI6CICIS3nFUNCTIONADDRESS8EIUCOMMENTS: Enter all alarm reportingcodes
FUNCTION ADDRESSNON-ALARM CODES*67NON-ALARM CODES *66❑ nml-(x,❑ lAC LOSS 2ND DIGIT❑ 0TROUBLE❑ nTROUBLE RESTORE❑ o BYPASS❑ 0B~PASS RESTORE❑ nRESTORE CO
FUNCTIONADDRESSTo disable Restore reports, program all locations in Addressee *69 -*71 as “O”.ZONE TYPES 1-4RESTORE REPORTENABLEZONE TYPES 5-8RESTORE
the 4+2 portion of the message is ever seen on the central stationreceiver’s display or printer. This High Speed 4+2 format is currentlyonly compatibl
NOTES:4. English language on the Ademco 685 Digital Receiver should not be used for most of these reports5. Note that B and C are not used for leading
FUNCTION4+2 EXPANDEDFORMAT ZONEEVENT DIGIT(Ist digit ofreporting code)17ADDRESS4+2 EXPANDEDFORMAT KEYPADPANICS/ZONEEXPANDER WIRINGSUPERVISORY EVENTDIG
FUNCTIONADDRESS4+2 EXPANDED*77Z9❑ nFORMAT ZONES9-16 ID DIGITZloncl(2nd digit ofreporting code)*II❑ uZ1213clmooZ14UUz15nnz16nclCOMMENTS: The second dig
FUNCTIONADDRESSFUNCTIONADDRESS4+2 EXPANDED*79FORMAT KEYPADPANICS/ZONEEXPANDER WIRINGSUPERVISORY IDDIGIT (2nd digitof reporting codeEIEIEIEIZeroes to b
FUNCTIONADDRESS4+2 EXPANDED*81FORMAT NON-ALARMCODES (CONT’D)“close” E desired on Ademco No. 685 Recewer or if closlng byuser is to be processed on an
FUNCTIONALARM COUNTTEST REPORTINITIATION TIMEADDRESS*82*83ADEMCO HIGH SPEED●84FORMAT USED ONWATS LINESDO NOT USE ’85ZONE EXPANDER*86TYPE SELECTION❑ oC
For each zone used, one of the following zone types must be selected:71. Entry/Exit Burglary (Delay #1). Assigned to sensors on doorsthrough which ent
After installation is completed, the Security System should be carefullytested.1. With the System in the disarmed state, check that all zones are inta
1. Fully explain the operation of the System to the user by going overspaces provided m the User’s Manual, record the Entry and Exil Delayeach of its
Two fuses (Battery fuse and Auxiliary Power fuse) are located on Iheunderside of the mam circuit board in the 4130 XT, To replace either ofthese fuses
DescriptionPart No.DC Power Pack -11 OV AC Input, 18V DCOutput (700 mA max output)No, 1350Aux Power Fuse (k Amp)No. 90-25Battery Fuse (2 Amp, slo-blo)
“FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT”This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC r
4130XT SECURITY CONTROL:1. Physical:2. ElectricalVOLTAGE INPUT:RECHARGEABLEBACK-UP BATTERY:ALARM SOUNDER”AUXILIARYPOWER OUTPUT:STANDBY:FUSES:Width:8.4
3. Intertace W\ring:RED:BLUE:GREEN:YELLOW:BLACK:4157 REMOTE CONSOLE:1. Physicel:Width:Height:Depth:2. ElectricalVoltage input:Current Drain:3. Interfa
4. Wiring Run Permitted to No. 4208 Zone Expander (or otherVECTOR RPMS):Wire GaugeMax. Wire Run22 (0.64 mm O.D.) 650 ft (200 m)20 (0.81 mm O.D,) 950 f
Wiring Connections:When the Security Control is cabinet-mounted, the flylng leads from the24-pin connector are connected to the interface wires via th
o 0—TB1— — TB2 —~W, TB3 ,000?REAR OFCONTROL—~24. PIN CONNECTOR(SEE DIAGRAM 1)GO:?ROLaT81CABINET (No. 4134-8)ORANGE1ZONE 1 + (WHEN NC SENSORS ARE USED)
The following is a description of the various zone types available whichmust be selected for each physical zone. You may w!sh to use Table A atthe end
WARNINGTHE LIMITATIONS OF THIS ALARM SYSTEMWhile this system IS an advanced design security system, It does not offer guaranteed protection against bu
●●●●Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagramed in their installationmanual. Passive Infrared
ADEMCOONE YEAR LIMITED WARRANTYAlarm Device Manufacturing Company, a Division of Pittway Corporation (“Seller”), 165 Eileen Way, Syosset, New York 117
ALARM DEVICE MANUFACTURING CO.A DIVISION oF PITTwAY cORpoRAT,~~165 Eileen Way, Syosset, New York 11791N3122.1 10/88Copyright ~ 1988 PITTWAY CORPORATIO
r-seconds A system-wide EEPROM defined number of alarmreports for this zone will be allowed to retransmitted (swinger sup-pression) by the communicato