The following reports (Addresses *55 - * 60) may be designated to raport aither in Standard or Expanded format. in aii cases, the Standard
message reports to tha Central Station a subscriber ID number and a report [e.g., alarm (see Address *55), trouble, restore, open/ciose] code.
The Expanded message reports a subscriber iD number, the report code, foilowed by a second line where the report code is repeated three or
four times and ia traiied by the chennel number (or user iD) reiated to that report. When 4+2 format is aeiected, no second iine is transmitted.
The channel number or User iD is sent as the last digit of the report.
Report
Alarm
Trouble
Bypass
AC LOSS
Low Battery
Open
Close
Cancel
Test
Power Up Reset
Program Tamper
Restore.
Alarm
3+1/4+1
Standard
SSS(S) A
SSS(S) T
SSS(S) B
SSS(S) E
SSS(S) L
Sss(s) o
Sss(s) c
Sss(s) x
SSS(S) Te
Sss(s) P
SSS(S) M
SSS(S) R
3+1/4+1
Expanded
SSS(S) A
AAA(A) Ch
SSS(S) T
TTT(T) Ch
SSS(S) B
BBB(B) Ch
SSS(S) E
EEE(E) Ac
SSS(S) L
LLL(L) LB
Sss(s) o
000(0) u
Sss(s) c
ccc(c) u
Sss(s) x
SSS(S) Te
Sss(s) P
SSS(S) M
Sss(s) R
RRR(R) Ch
4+2
SSSS ACh
SSSS TCh
SSSS Etch
SSSS EAc
SSSS LLB
Ssss Ou
Ssss Cu
Ssss Xo
SSSS TeO
Ssss Po
SSSS MO
SSSS Rch
3+1/4+1
Report Standard
AC
LOSS
SSS(S) R
Low Battery SSS(S) R
Trouble
SSS(S) RT
Bypass
SSS(S) RB
Where,
SSS or SSSS = Subscriber ID
A = Alarm Code
O= Zero
Ch = Channel Number
T = Trouble Code
B = Bypass Code
E = AC Loss Code (1st Digit)
AC = AC Loss Code (2nd digit)
X = Cancel Code
P = Power Up Reset Code
M = Program Tamper Code
3+1/4+1
Expanded
4+2
SSS(S) R
SSSS RAC
RRR(R) Ac
SSS(S) R SSSS RLB
RRR(R) LB
SSS(S)RT SSSS RTCh
RTRTRT(RT)Ch
SSS(S)RB SSSS RBCh
RBRBRB(RB)Ch
L = Low Battery Code (i st digit)
LB= Low Battery Code (2nd digit)
O = Open Code
C = Close Code
U = User Number
Te = Test Code
R = Restore Code (Alarm,
AC Loss, Low Battery)
RT = Restore Code (Trouble)
RB = Restore Code (Bypass)
Comentarios a estos manuales