FUNCTION
ADDRESS
POWER UP IN
●28
PREVIOUS STATE
QUICK ARM
●29
TOUCH-TONE OR
●3O
ROTARY DIAL
PABX ACCESS CODE*31
❑
COMMENTS: If selected (YES), on power-up the system w(II assume system status prior to power down. If not
selected (NO), the system w(II power up in disarmed state.
Enter O (NO) or 1 (YES),
When the system powers up armed, an alarm WIII occur 3 minutes after arming If a zone is faulted, When so
armed, reports closing as User #7 if open/close reporting for User #7 was enabled in Address *52.
❑
COMMENTS: Enables arming of the burglary system in any mode without use of a Security Code (just # key
depression followed by the command AWAY, STAY, INSTANT or MAXIMUM). When armed AWAY or MAXIMUM,
reports closing as User #7 (f open/close reporting for User #7 was enabled m Address *52,
Enter O (disabled) or 1 (enabled).
•1
COMMENTS: Permits selection of the type of dialing to be used.
Enter 1 for Touch-Tone, O for Rotary.
❑ 0 ❑ 0 ❑ 0 ❑ 0
COMMENTS: If not required, enter nothing and proceed to next address; otherwise, enter prefix needed to obtain
an outside Telco line. This field may be used alternatively to enter a prefix that can suppress the Telco’s call wait-
ing feature from interfering with outgoing transmission. This prefix is only useful if the Telco option to be able to
suppress call waiting has been obtained by your customer. The prefix to be used is 1170 if pulse dialing is being
used or *7O if TouchTone@ dialing is being used
Enter up to 4 digits, Each digit requires a 2-digit entrj so as to allow entry of hexadecimal digits (B-F) Use the fol-
lowing chart to determine the entry for each dlglt. Only enter digits required Do not fill unused spaces. Erase the
field by entering *31*.
-—-
—
—. -.
Comentarios a estos manuales