7. If a trouble condition occurs in Zone 4 for subscriber #5890 and Zone
4 was assigned 10 Channel 2, a trouble report is transmitted.
Subscriber
Channel Number
Identification
1234 5676 9
Message:
5890
5155 5555 5
Trouble restoral is transmitted as soon as it occurs.
5890
5355 5555 5
8. If a system trouble condition occurs, a separate trouble message for-
mat exists.
Subscriber
Channel Number
Identification 1234 5678 9
For Loss olACReporting (Channell is used)
Message:
0135
1555 5555 8
For AC Restorai
Message:
0135
3555 5555 6
ForLowBattery Reporting (Channel 2 is used)”
Message: 0135 5155 5555 6
*Low battery is not only determined when AC power is off and the battery
is being discharged, It is also tested for byperiodically (at the interval
selected in Address #27) removing ACpower briefly to check battery
status.
For Low Battery Restorai
Message:
0135
5355 5555 6
For Program Tamper (Channel 3 is used)
Message: 0135 5515 5555 6
For Power Up Reset (Channel 4 is used)
Message:
0135
5551 5555 6
NOTE: Restorals are not applicable to Program Tamper and Power Up
Reset.
9. At Subscriber #5890, Zone 12 assigned to channel f 3 goes into alarm
and Zonell assigned tochannel 11, which hasprevlously reported
an alarm has restored.
Subscriber
Channel Number
identification
1234 5678 9
Message:
5890 5553 5155 1
10, At Subscriber #0135 a test message is initiated.
Subscriber Channei Number
identification
1234 5678 9
Message: 0135 5555 5555 9
FUNCTION
ADDRESS
ALARM REPORT
*55
❑
COMMENTS: Enter O(Standard Report) or 1 (Expanded Report).
When Expanded is selected, the channel number is transmitted in the last position of the 2nd transmission line (or
of the lsttransmission line if4+2 Format is used).
NOTE: Selection applies to both primary and secondary phone numbers.