ZONE 6: Ths zone maybe programmed to sewe as a tamper loop for the C-COM c;ibinet
ALTERNATE TAMPER and for the Ademco AB12 grade A burglary bell box. For Grade A Burglary
FUNCTION
installations, field Y17 must be programmed to “l” to enab[e this function and
,-
zone 6 should be assigned a day/night burglary res~nse (zone type
05). The
panel will initiate a day trouble/night alarm when an open or short circuit is
detected in this zone or when an earth ground fauk caused by tampering with the
AB12 burglary bell box is detected. See the BELL CIRCUIT OUTPUTS setion for
AB12 bell wiring information.
ZONE 7: This zone may be programmed to sewe as a keyswitch input. See the REMOTE
ALTERNATE KEYSWITCH section for keyswitch programming, wiring and operating
KEYSWITCH FUNCTION
information.
ZONE 8
This zone has the added capatifify of supporting 2-wire latching type glass break
TWO WfRE GLASS detectors. Use detedors which are wmpafible with the ratings fisted below. The
BREAK DETECTORS second ent~ of an OFF sequewe wilf interrupt zone power to allow detedors to
reset followiW an alarm.
Compatible Z-wire Glass Break Detectors
Standby Voftage: 5VDC - 14VDC
Standby Resistance: Greater than 20k ohms (equivalent resistance ~ofall
detectors in parallel)
Alarm Resistance: Less than 1.lk ohms (see note below)
Alarm Current 2 MA -10 MA
Reset Tree: Less than 6 semnds
The IEl 735L series detectors have been tested and found to be compatible?with
these ratings. Up to 50 IEI 735L deteaors, mnnected in parallel, maybe used
(the alarm current provided by this zone is sufficient to support operation 0[ only
one detector in alarmed state). Follow the manufacturers recommendatiot~s on
proper detector installation.
NOTES:
. Detectors which exceed 1.1k ohms in alarm, but maintain a voltage drop in
alarm of less than 3.8 votfs can also W used.
. Use of N.O. or N.C. contatis on the same zone may prevent proper glass
break detector operation.