To ADD a Master,
Manager or Operator
cod=
To CHANGE a Master,
Manager or Operator
code:
To DELETE a Master,
Manager or Operator
code:
To WEW User
Authori& Level
Enter Installer Code + [8] + new User # + new Usets code
(ex. 5140+ [8]+ 02 + 1234)
Console will prompt for Authority level. Enter the desired level number from the
table above
Console will then prompt for Open/Close reporting optiont. Press O (NO) or “Y’
(YES). The console will display the user ID number and associated authority level
when the new code has been successfully entered.
Enter Installer code + [8]+ User number+ new code for that user
The system will detect that the user number is already assigned and will prompt if
this is a new user. Press O (NO). The system will then confirm that the change is
allowed based on authorization level. If the user number is the same as the
Installer’s, the system will prompt for the new code to be reentered. This prevents
accidentally changing a high level code.
Enter Installer code + [8] + User number+ Installer code
The system will prompt if this code should be deleted. Press O (NO) or 1 (YES). [f
yes, that users code will be removed and the authority level and all other
information about that user will be deleted. Note that a user can only be deleted
by a user with a higher a~thority level. A user cannot delete himseM.
TO EXIT THE USER CODE ENTRY MODE, either press [*] or [#], or
don’t press any key for 10 seconds.
Once a user code has been programmed, its associated user ID number and
authority level can be viewed by enteting that user’s code + ~] + ~].
User numbers must be entered as 2-digit entries. Single digit user numbers
must, therefore, always be preceded by a “V (example, 03, 04, 05, etc.). Make
sure the end user understands this requirement. Tempora~ codes are entered
as 4-dfgit numbers.
IMPORTANT!: Unless Ademco Contact ID repofiing is used, only user code,
#1 #15 can uniquely report to the central station using the communicafionw
formats provided. Users #16 - #99 will repofl as User #15, if enabled for
open/close reporting, for the other repoding formats.
IMPORTANT!: During user code ent~, normal key depressions at other
consoles will be ignored. However, panic key depression will cause an alarm and
terminate user entry.
t OP”EN/CLOSE REPORTING NOTE: When adding a user, the SyStem will
only prompt for OpetiClose reprt capabilfiy if the user is being added by the
Installer. When a Master or Manager adds a new user, the new users OpeWCbse
re~rfing enable will be the same as that of the Master or Manager adding the
user. If Open/Close reports are required to be selectable by the Master or
Manager, the Installer should assign two Master or Manager user codes: one with
Open/Close repofling enabled, and one without Open/Close repoting.