ADEMCO Alpha Vista Console Manual de usuario Pagina 33

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 74
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 32
V. SYSTEM OPERATION
,.-
GENERAL
INFORMATION
IINSTALLERS CODE
(lISER #1/Authorl@
Level O)
SECURIW ACCESS CODES
The 5140XM system allows up to 99 4-digit security access codes to be
programmed. When programmed, each code is assigned a user ID number and
an authority level, which determines the system functions that code can be used
to perform. There are seven authotity levels as fisted in the table below. Aside
from the installer, who programs codes at installation time, the system allows
master and manager level users to program codes on an as needed basis. These
codes are intended for use by those who need limited and/or temporary control
over system operation.
A Quick Arm feature can also be programmed (field ’29) which enables the [#] key
to be pressed instead of entering the security code when arming the burglaV
system. The security code must still be entered when disarming the system. Note
that open/close reporting of Quick Arm is enabled if User 2 is enabled for
open/close reporting, and that Quick Arm repons as user O.
TABLE OF AUTHORITY LEVELS
kvan Itle Enter Armml=rm
S!lmm
dlCh
ang B Act!vate
Pro ram
tMO e
e %urlfy ZO~e~
TestModes
:;f:~ ::PT2
ties
Trouble
O-lnsmlbr yes
Yp, m
y-
d]sam only if L?;?ay E$%~
~g;;:alk
u=d b m
ititing fue zones
if tests,tiredill
installerlevel maw)
1-tister
m
yes yes yes,levels2-
ye~,b“~
6Wly
y=,
buq.
zow (md
walk tes!, tire
fire zones if
dtill only
maH&)
2-Maager
m
yes
yes
~;;yls %
y=, burg b
Y
zmes Mb
Uali t$s?
3a per~w A
m
yes
yes
m
yes, burgla~
m
zones mly
4ap eratw B
m
Y
Ves m
m
m
~peramr G m y;, m
dtsam only
if
yes
m
m m
u=d to am
%-Duress
m
yes, sen&
yes
m
m m
s]lent Wnic
Epon
As shipped from the factory, the installer’s code is pre-programmed to 5-1-4-0
and can be changed by the installer to any desired code (field .00).
The installer’s code is intended to be known and used only by the installer and his
aPPointed se~ice representatives. Durin9 intial installation, the installer uses this
code to program security codes for master, manager and lower level users who
will operate the system on a day to day basis (see procedures following). The
installer’s code is the only code that permits entry into programming mode, where
the system’s operating parameters can be changed. The installer’s code is also
the only code which permits fire system walk test ati!vafion and can be enabled to
permit fire sensor and system zones to be bypassed (field 3.85), The installer’s
code can be used to perform all normal system functions except that, for added
security, this code can be used to disarm the burgla~ system only if it was used to
arm the system. Note that open/close reporting for the installer is enabled in field
.39.
The system also provides an [nstaller Code lock-out feature, which prevents the
use of the Installer’s Code from re-accessing the Programming mode after the
initial programming. This feature is activated by pressing ’98 to exit Programming
mode. The only way to access Programming mode once this feature is activated,
is by powering down the system and powering up again, and then pressing both
Ihe and # keys at the same time wifhin 30 seconds of power up. If re-access to
Programming mode using the Installer’s Code is desired after initial programming,
then exit Programming mode by pressing “99.