ADEMCO Alpha Vista Console Manual de usuario Pagina 47

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 74
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 46
GENERAL
INFORMATION
LOADING
IGOMMUNICATION
DEFAULTS
To help expedite the installation, Ademco has incorporated 4 different
communication defauffs in the Control (Low Speed, Ademco Express, Ademco
High Speed &Ademco’s new Contacted). These defaults automatically program
indust~-standard code assignments for zones, keypad panics, non-alarm and
supervisory conditions, and can be loaded at any time without affecting non-
communication program fields. Using these defaults saves programming time!
After loading one of the communication defaults, you only need to wire the
devices to their appropriate zones, and program the following:
. Central station phone number(s), fields”33 & ’34
. Subscnbe~s aaunf number(s), fields’32 &*90
. Zonety~ responses, fields ‘02-’05, 1’01-1’05 & 710
.Belll, Be112and Aux Relay assignments, fields Y15, V61,3’70-3’81.
. Delay s, timeouts, ati miscellaneous ~ntrol options.
The system is then operational.
NOTE: Defauff communication wmmands are in second set of programming
fields (fields 1’80, 1’81, 1“82 & 1“83).
Once the Programming mode is entered, clear tha system’s memory by pressing
“97. TMsensures allprogram tieldsare settotheir factoVset, pre-programmd
values. If desired, foadone of thecommunication defauff programming sets by
first changing to the 1’XX set of fields (press ‘94), then entering one of the
following field numbers:
The program fields that are affected by loading one of the communication
defaufts are fields’45 -’82, 1’40,1.41740-3’42, 3’50-752. Defauk values for
each communication default are listed at the end of this manual. For detailed
information about reporting formats, see the SYSTEM COMMUNICATION
section. Affer loading one of the defauff sets, proceed to program the system
data fields as described in the PROGRAMMING DATA FIELDS section.
EA,SY-TO-PROGRAM
COMMUNICATION
FIELDS
The programming scheme eliminates the need to program zones to channels,
and then channels to codes. If programming communication fields manually,
simply enter whatever code (3+1, 4+1, 4+2 or Ademco Express) is to be sent for
each zone (including panics, non-alarm males and supervisory codes). NOTE:
Enter”1 O to transmit an “W, which appears as “O at the receiver.
All zones are separated into groups of 8, with common rastore, trouble and
bypass codes for evey 2 groups (16 zones). There are 2 double-digit entries for
each code. For 3+1, 4+1, 4+2 and Ademo Express, the first entry is the alarm
code for a standard reporf. The second entry is the ID digit for an expanded 3+1
or 4+1 re~rt, or for a 4+2 or Ademco Express report. If the second digit is O,
only 3+1 or 4+1 (or 4+1 express) non-expanded messages will be sent. If only
three digits are entered in the account number field, the ID or second dgits are
ignored, if entered. For Ademco Mgh Speed format, the first digit entry is the
channel assignment for that zone, and the second digit is ignored, if entered.
For Contact ID reporting, the first digit entry (any non zero entry) enables
reWrting for that zone, and the second digit is ignored.
NOTE: Restoral reports for an event will not be sent if the event ifse!f is not
enabled, even if a restore code is programmed for that event.
.-