PASSIVE INFRARED Refer to the PIR Installation Instructions for installation hints” as to the best
MOTION DETECTORS mounting Iocation forthese devices.
4278 Quad Element Polling Loop PIR
,.-
Quad element PIR with built-in RPM which is DIP switch programmabh? and
mnnecfe drectlyto the polhng hop. Includes mirrors for both wide angl~?and
cudain/long range applications. NOTE: The built-in auxihary aensorloop ia not
supewieed and should Mt be used.
4275 Dual Elament Polling Loop PIR
Dual element PIRwith built-in RPMwMch is DIP switch programmable. Includes
mirrors for both wide angle andcutiaitilong range apphcafions andcan use the
1875PA Pet Alley mirror. Built-in selectable pulse count capabitify.
MISCELLANEOUS
4194 Surface Mounted Reed Contact (Wide Gap)
POLLING LOOP Wide gap surface mounted reed confacf with buik-in RPM, which is DIP switch
DEVICES programmable.
4190WH Two Zone Remote Point Module
Used to supewise conventional N.O./N.C. devices via the polling loop, and has a
tamper supervised cover.
Provides one class B (style B) supervised (Ieft)loop for monitoring fire alarm,
sprinkler superviso~ and burglary senmrs. NOTE: N.O. fire/sprinkler devfces met
be (style B) supervised using a 4.7k EOLR (model 610;11; purchased sepiirately
as pati of 41OOEOLR Resistor ~t~. N.O. and N.C. burglary devices may be
supewised using either a4.7kor30k EOLR. Note that the second unsupewised
(right) loop should not be used. DIP switch programmable zone nutier.
4208 Eight Zone Polling Loop Expansion Module
Used to supervise conventional N.O./N.C. devices via the polhng loop. Provides 8
class B(style B) supervised Ioopsfor monitoring fire alarm, sprinkler supe!visov
and burgla~ sensors.
NOTE: The fhst six krops are (style B) supervised using a4.7k EOLR arid can
monitor either N.O. fire alartisprinkler supervisory devices or N.O./N.C. b~jrglary
devices. The last two loops are supervised using a 30k EOLR and can only be
used to monitor N.O.W.C. burglary devices.
Note that the 4208 must either be mounted inside the 5140XM cabinet <Irin a
separate enclosure which hasatamper supervised cover when used to monitor
burglary devices.
DIP switch programmable zone numbers. The first two loops can be selected for
either normal or fast response (DIP switch selectable).
4197 Polling Loop Extender Module
At present, the4197 is UL Listed for burgla~ appticafions only. Can be used if the
2-wire polhng loop must be greater than the recommended length (4000 mm). By
instalhng a 4197 at the end of the first loop, the polfing loop can be continued. If
more than 64mA needs to be drawn from the pelting loop to power RPMs, use of
the 4197 p,~vides a~fher loop with 64mA available. Connects to the polhrlg loop
and must be Wwered from auxifiay power #l output.
-11–