#93 USER FRIENDLY MENU MODE
GENEW INFORMATION After programming all system related programming fieUs in the uwal way, pres
W3 to display the first choice of the three menu driven programming funtions,
which are: Zone Programming (for programing zone types), Alpha PmgramfiW _
(for prqramming alpha descriptors) & Device Programming (for programming
console characteristics). Press O (NO) or 1 (YES) in res~nse to the selection.
Pressing O will display the next choice in sequence. Refer to the ZONE
PROGRAMMING section for instrutilons for programming zone characteristics,
the DEVICE PROGRAMMING section for instructions for programming remote
consoles, and the ALPHA PROGRAMMING section for programming alpha
descriptors. The hst of commands used while in the menu mode is shown at the
right.
zoNE PROGmMMING
The following fields can be programmed by using the ZONE PROGRAMMING
Menu Mode:
1,
2.
3.
4.
ZONE PROGRAMMING FIELDS
‘02-’05
Zone response types for zones 1-27, 95-99
1’01-1.05
I
Zone response tvpes for zones 28-M
3’10
Zone reswnse typ
es for system zones 70-75
Enter Programming mode, then press *3 to display “ZONE PROG?”. Press
1 to enter ZONE PROGRAMMING rode,
Enter the zone number to be pr~rammed (01-~, 70-75, 95, 96,97 or 99).
Press p] to accept entry,
Enter the zone response type for that zone (01 -19). The screen will
automatically dsplay the zone type for the number entered. Press p] to
accept ent~. If a different zone res~nse type is desired, enter a different
number and press ~].
The display will repeat with the zone number question for programming the
other zones in the system. Enter 00 to exit back to normal programming
mode.
-.
W3 MENU MODE KEY COMMANDS
m
Enters Menu mode
[*] Sewes as ENTER key, Press to have console accept entry.
[#]
Skips to next screen displav
without changing existing entries,
o
Press to answer NO
f
Press to answer YES
0149
All entries are 2digit entries
00
Ewapes
from menu mode. back into field programming mode
DWICE
PROGRAMMING
NOTE 1: Console 10 number 00 is permanently enabled and set for no sounder
suppression. TMs cannot be changed.
NOTE 2: The panel is factory pre-programmed with all console ID numbers (01-
30) enabled and set for no sounder suppression. Use the DEVICE
PROGRAMMING mde ‘at initial installation only if it is desired to change
the sounder options for one or more
mnsoles
1.
Enter Programming mode, then press H3 to display “ZONE PROG?”. Press
O (NO) to display “ALPHA PROG?”. Press O again to display “DEVICE
PROG?. Press 1 to enter OEVICE PROGRAMMING mode.
2. Enter the 2-digit console ID number as set by its DIP switches (01-30). Press
p] to accept entry.
3.
4.
5.
Enter 01 and press ~]. Enter 01 again and press ~].
Enter a number 00-03 for the console soundhrg suppression options desired
for this console as follows:
Enter 00 for no suppression.
Enter 01 to suppress artidisann & entry/exit beeps.
Enter 02 to suppress chime mode beeps only.
Enter 03 to suppress ar~disarm, entry/exit and chime ~de beeps,
The screen will display the next console number to be programmed.
press 00 to exit Menu Mode.
–50–