1
EWNT LOGGING PROCEDURES
IMPORTANT: In order for time and date stamping to occur, the system’s real-time clock must be set.
Refer to the SETTING THE REAL TIME CLOCK section for details.
GENERAL The system has the atihty to record vafious events in a histo~ log (224 eveniu
INFORMATION
capacity) wherein each event is recorded in one of five categories (alarm,
supewiso~/check, bypass, open & system), with the time and date of its
occunence (if real-time clock is set). The log maybe viewed (Display Mode) on the
alpha console, or can be ptinted (Ptint Mode) on a sefial ptinter (connected to the
system via a 41 OOSM Serial Module; see TRIGGER OUTPUTS section for
connection details).
EVENT LOG MODE COMMANDS
Display Mode: Enter user code + [#]+ [6] + [0]
Print Mode: Enter user code + [#]+ [6] +
[1]
Clear Event Log: Enter user code + [#] + [6] + [2]
To EXIT Event Log Mode: Press [*] at any time.
PROGRAMMING The system can be configured for the following event log activities
.
.
.
.
.
To-either record even~s but not print them unless commanded to do so, or to
automatically ptint the events as they occur (field 1’72).
Specific categories of events to be logged can be selectively enabled (field
1.70).
The time stamp can be programmed for either 12 or 24 hour formats (field
1’71).
The printer baud rate can be set to either 300 or 1200 baud (field 1.73).
Set event log fime/date repoti enable (fields 1-40& 1’41 ).
Enable reDoflino of event Ioa caDacitv (i.e.. 50”/0 full, 907~ full & overflow)
programmed in fields 1“40 & 741 ~ -
EWNT LOGGING Afler entering either mode, the following will be displayed:
DISPLAY & PRINT
‘oDES ~
The Event Log holds up to 224 events, and can display
ptint all events in a catego~ (complete), or only tho~w”
events in a catego~ occurflng since the last Clear Event
Log command (recent). Note that once the Event Log is
full, the oldest event will be erased upon the logging of any
new event. Press the desired display mode key, O or
1.
For display and printing purWses, events are grouped
into five categories as follows. Use the [3] & [1] keys to
scroll to the next or previous category screens
~ ~~~~~ebeenrestored.
Displays time/date for zones that have either caused an
~
Displays time/date for zones that have caused a trouble
or fire supewiso~ condition.
~
Displays time/date for zones that have been bypassed.
~
Displays time, date and user number for each arming and
disarming of the system.
~
Displays fime/date for system problems, such as AC
Loss, communication failure, etc.
~
Displays all categories of events in chronological order,
from most recent to oldest.
SCREEN DEFINITIONS
RECENT
Events since last CLEAR
COMPLETE Displavs all events
WPE
Type of event (Burg., fire, etc. )
-,
ccc
Zone (contact) number
Uuu User number
-40–