Ml\STERfMANAGER As shipped from the factory, there are no master or manager codes pre-
~SODES (Authority
programmed. The installer must program at least one master code during initial
Levels 1/2) installation.
Generally speating, the Master Code is intended to be known and used by the
building owner. Themanager code isintended to be known andused by the
building superintendent, the building security officer or the like. These codes
allow full control over burglay system operation. They can be used to program
Iowerlevel codes on arias needed basis, for use by those who need limited
and/or temporary control over system operation such assupewisors, employees,
cleaning personnel, tenants, etc. To add, change or delete user codes, follow
the procedure described in the INSTALLER CODE paragraph, substituting
master or manager code for the installer code. Note that a master user can
program codes for a manager or lower level user, and cannot change a master
level code. A Manager can program codes foranoperator ortorduress, and
cannot change a manager level code.,
Master Codes and all Iower level codes can be used interchangeably when
peflorming system functions (a system armed with an operator’s code can be
disarmed with the Master Code), with the exception of the Operator C Code
described later in this section.
OPEN/CLOSE REPORTING: Note that open/close reporting enables for
added users are the same as that of the master or manager adding the new user.
OPERATOR CODES
Operators can arm and disarm the system to the authority assigned, but cannot
(Autllority Levels 3-5)
addormodify any user. lfOperator C isselected, that operator’s code cannot be
used to disarm the system urrless the system was armed .with that c~de. This
code is usually assigned to persons who may have the need to arm and disarm
the system at specific times only.
OPERATOR LEVELS OF AUTHORIW
Level Title
Functions Permitted
3 Operator A
Arm. Disarm, Bypass
4 Operator B Arm, Disarm
5 Operator C
Arm, Dsarm only if armed with
same mde
DURESS CODE
The duress code is a means of sending a silent alarm to a central monitoring
(liuthority Level 6) station if the user is being torced to disarm (or arm) the system under threat. This
feature is only useful if the system is connected to a central station using the built-
in dialer or a LORRA. Duress has its own unique report when digitally
communicated, but issignaled onthesame trigger that signals silent panic when
communicated viathe LORRA. When used, thesystem will disarm (or arm), but
will also send asilent alarm tothecentral sfation. There will benoindicafion at the
console that an alarm was sent.