WHAT CAN BE DONE . Arm the System in the Away Mode; Disarm the System
ONCE PANEL IS
. Bypass a Zone
lION.LINEII?
. Force the System to Accept a New Program Download
,-,
. Shut Down Communication (dialer) Functions (non-payment of monitoring fees
in an owned system)
. Shut Down all Seedrify System Functions (non-payment for a leased system)
. InMbit Local Keypad Programming (prevents takeover of your accounts)
. Leave a message for customer
. Command the System to Upload a Copy of ifs Resident Program to the office
. Read: Arming Status, AC Power Status, List of Faulted Zones, Lfst of Bypassed
Zones, 224 Event Log, Dst of Zones Currently in Alarm, List of Zones Currently
in Trouble
. Set the Real-Time clock.
HOW SECURE IS
Accessing the Control from a remote location is protected against compromise by
DOWNLOADING? the use of 4 levels of protection:
1.
2.
3.
4.
Security Code Ha~dshake: The subscribers account number as well as an 8-
digit ID number (known only to the office) must be matched between the
Control and computer.
Hang-Up and Call-Back: The Control panel will “hang-up” and call the
computer back at the pre-programmed number only if the security codes
match.
Data Encryption: All data that is exchanged between the computer and Control
is encrypted to reduce the possibility of anyone “tapping” the line and
corrupting data.
Operator Access Levels: Up to 15 operators can have accesa to the
DOWNLOADER, each having their own log-on code. However, each
operator can be assigned one of three levels of access in both FILE and
COMMAND functions, as follows:
FILE ACCESS:
Read Only: able only to look at the database; cannot change any informatkm,
and cannot see the customets access codes.
Part Read/Write: able to look at and change all information. except the
customer’s access codes.
Full ReadWrite: able to look at and change any and all information in the
database.
CONTROLICOMM ACCESS:
Read Only: able only to Upload and arm the system. Not able to DISARM,
BYPASS, or change any information.
Parf ReadWrife: able to ARM, BYPASS, UPLOAD, DOWNLOAD but cannot
shutdown the system.
Full ReaWrite: able to perform all control and status commands, as well as
shutdown all or part of the system.
NOTES:
1
2.
3.
4.
5.
Each time the Control panel is accessed (whether successful or
unsuccessful), aPROGRAM TAM PERreport~81) issentto central station, ti
programmed.
When downloading, the console displays
“MODEM COMM”.
Whenever a download or
a save is done, an automatic time stamp is done,
indicating the date and time of the last download (or save) and the operator ID
number.
Theaverage time foracomplete download, includng initial call-up, hang-up
arid call-back is under 4 minutes.
A complete hard copy of each individual account can be obtained by
connecting aprinterto the computer. Refer toyourcomputer owner’s manual
or mntact your dealer for printer recommendations.