IWMOTE =YSWITCH An optional UL Listed remote keyswitch ~n be used for remote armin@disarmiW
OPE-TIONMIRING of the burglary portion of the system and for remotely silencing alarms. If used,
program fieti “15 mu~ be set to “1- or “2” to select a keyswifch operating mode.
,-
Zone 7 must be assigned a non-zero response type. Also, fie~ 3’20 must b set
to ‘1” t it is desired to use J20UT 1,5 to o~rate keyswifch ARMED a~ RFADY
LEDs (if keyswitch provides LEDs). The keyswitc~s normally open momentary
switch ad LEDs (it used) must be connected to zone 7 and to J20UT 1,5
respectively as shown in the diagram bbw. An optional cbsed circuit tamper
switch (ex. Adem ~. 112) can be wired in series wth zone 7 so that keyswifch
operation will be dbsblad when the swfichplate is remved from the wall.
The 5140XM allows 2 modes of keyswitch operation. When field ’15 is set to ‘1-,
the keyswtich operates as follows:
With System Disarmed and No Alarms Present:
A momentary short across zone 7 will arm the system in the AWAY mode, and a
short held for more than 3 seconds will arm the system in the STAY rode. A
subsequent short will disarm the system. The keyswitch LEDs will indicate that
the system has armed (see table below). NOTE: FauRed zones must ei~r be
comecfed or bypassed before the system will arm.
.,-
With Alarms Present:
A momenta~ skrt across zone 7 will silence alarm bell and mnsole sounds, ati
will disarm the system if t was armed. The keyswfich LEDs will provtie a memory
of alarm indication (see table bebw). A subsequent short across zone 7 will clear
the alarm memory indkkation and reset 2-wire smoke am glass break detectors (f
used).
When field ’15 is set to “2”, the keyswitch operates as follows A mmenfary short
across zone 7 will silence slam ball sounds ~.e. turn off Bell 1, Bell 2 and aux relay
t programmed for alarms) only ti a fire alarm is present. Outputs remain siltmcad
until a code + OFF is entered to reset alarms and clear alarm displays. A
momentary short has no effect if there are no fire alarms present. Thb mode is
intended to be used where it is desired to provide the fire deparfmenu with
keyswitch silence capsbi~iy wtihout compromising the burglary system’s semrify.
LED indications are defined
as follows:
GREEN RED
MWING
OFF OFF
DBARMED & NOT R~DY
m OFF DISARMED & R~DY
OFF
ON STEADY ARMED AWAY
OFF SLOW FLASH
ARMED STAY
OFF RAPID FLASH MM MENRY
NOTE: Open/close reporting for keyswitch is enabled in field ’40, and the keyswfich
reptis
as user O
figure 8. KWSW~CH WIRING
If “w W5.16 .75,. .1. or .2. for dad kwstich retie
m, field 3.20 to ,,t. to .“*I. ED d“w (KLED“~)
J2 CONNECTOR
–21-