VISTA-128BP/VISTA-250BP Installation and Setup Guide
7-4
Scheduled Download
The VISTA-128BP/VISTA-250BP can be programmed
to periodically and automatically call the downloader.
When this option is set up, the system will call the
downloader at a scheduled time. Once the connection is
established with the modem, the downloader controls
which functions are performed (download, arm, upload
event log, etc.).
The programmable options for the scheduled download
are located in the
#93 Menu Mode
section under the
main menu prompt
Scheduled Check-in.
The options are as follows:
Check-in interval (weekly, monthly quarterly,
yearly)
Quarter of the year (if quarterly is selected)
Month of the year (if monthly, quarterly, or yearly
is selected)
Day of the month (if monthly, quarterly, or yearly
is selected)
Day of the week (if weekly is selected)
Time of day
Refer to the
#93 Menu Mode
section in the
Programming Guide
for sequence of the prompts.
Direct-Wire Downloading
The VISTA-128BP/VISTA-250BP can be downloaded
without using a modem or telephone line by using a
4100SM Serial Module and Compass Downloading
Software. The direct-wire downloading connection is to
be temporary, and is not part of the permanent
installation. Direct-wire downloading is meant as a
tool for the installer during the installation process.
The connections between the control and the
4100SM are different than those shown in the
4100SM Installation Instructions. See
Figure 7-
1
for the correct connections. In addition, in
place of the green wire, referred to in step 2 of
the IN CASE OF DIFFICULTY section of the
4100SM Instructions, use the violet wire
instead.
Connector J8 on the main PC board (see the
Summary
of Connections
diagram on the inside back cover of this
manual) is intended to be interfaced to either a local
serial printer (see
SECTION 3:Installing the Control
) or
a computer. Make connections to a computer as shown
below.
Note that the violet wire connection for a
computer differs from that used when connecting
a serial printer.
Remove the VA8201 Alpha Pager Module, if it
is installed, before performing the direct-wire
download. It may be reconnected once the
direct-wire download is completed.
123456789
NU
J8 CONNECTOR
VIOLET
GRAY
YELLOW
RED
GREEN
BROWN
BLUE
BLACK
IN 2
GROUND
IN 3
GROUND
OUT 5
OUT 6
GROUND
GROUND
PRINTER DTR
4142TR CABLE (SUPPLIED WITH 4100SM)
8
7
6
5
4
3
2
1
4100SM SERIAL MODULE
+ PWR
- (GND)
RXD
not used
not used
TXD
not used
not used
RED BLUE WHITE
To TB6 Aux. Power (+)
(25mA current draw)
To TB7 Aux. Power (-)
Figure 7-1: Direct-Wire Downloading Connections
Telco Handoff
Telco handoff is another method of getting on-line with the downloader. The installer or customer enters the
User Code
+ [#] + [1]
, while on the phone line with the computers modem phone line. The customer will get cut-off and the panel
and download computer will establish a connection.