VISTA-128BP/VISTA-250BP Installation and Setup Guide
5-6
FIELD
TITLE and DATA ENTRIES EXPLANATION
*52
Standard/Expanded Reporting
Primary
0
= disable
1
= enable
This field has six entries as follows: Alarm, Restore, Bypass, Trouble,
Open/Close, Low Battery. If enabled, expanded reports are sent to the
primary phone number if low speed format is selected in field *45.
NOTE:
Expanded overrides 4+2 format.
*53
Standard/Expanded Reporting
Secondary
0
= disable
1
= enable
This field has six entries as follows: Alarm, Restore, Bypass, Trouble,
Open/Close, Low Battery. If enabled, expanded reports are sent to the
secondary phone number if low speed format is selected in field *47.
NOTE:
Expanded overrides 4+2 format.
*54
Unattended Mode
0
= disable
1
= enable
If enabled, the system automatically calls the downloader at programmed
intervals.
NOTE:
The following fields must be programmed first: primary
subscriber account number – field *32; primary phone number – field *33;
downloader phone number – field *35. Or you can go into the Unattended
Program Mode, from normal operating mode, by entering Installer Code +
[#] + [8] + [9].
*56
Dynamic Signaling Delay
Enter
00-15
times 15 seconds.
Select the time the panel should wait for acknowledgment from the first
reporting destination before it attempts to send a message to the second
destination (first and second destinations are determined in field
✳
57).
NOTE:
If the acknowledgment is received before the delay time expires,
no message is sent to the second destination.
*57
Dynamic Signaling Priority
0
= Primary Dialer
1
= Long Range Radio
Select the initial reporting path for central station messages.
*58
Long Range Radio Central
Station #1 Category Enable
0
= disable
1
= enable
This field has six entries as follows: Alarm, Trouble, Bypass, Open/Close,
System, Test. If enabled, the reports are sent to the primary subscriber
ID of the Long Range Radio.
*59
Long Range Radio Central
Station #2 Category Enable
0
= disable
1
= enable
This field has six entries as follows: Alarm, Trouble, Bypass, Open/Close,
System, Test. If enabled, the reports are sent to the secondary subscriber
ID of the Long Range Radio.
*79
Zone Type Restores for Zone
Types 1-8
0
= disable
1
= enable
This field has eight entries, one for each zone type. Select the zone types
that will send Restore reports.
*80
Zone Type Restores for Zone
Types 9, 10 and 16
0
= disable
1
= enable
This field has three entries, one for each zone type. Select the zone types
that will send Restore reports.
*83
First Test Report Time
Enter
00-07
the for day (01 = Monday)
Enter
00-23
for the hour
Enter
00-59
for the minutes
Enter the day and time that the first Test report shall be transmitted.
Enter
00
in all locations if the Test report is to be sent immediately upon
exiting. Enter
00
in the day location if the report is to be sent at the next
occurrence of the time that is set.
*84
Swinger Suppression (partition-
specific)
Enter
01-15
.
Enter
00
for unlimited reports
This option limits the number of messages (alarms or troubles) sent for a
specific zone in an armed period. The system automatically resets the
shutdown for a zone after 48 hours if there are no trips on any zone.
Must be
00
for UL installations.