Section 2 Partitioning and Panel Linking
2-7
Multi-Panel View Mode
To perform a function in the Multi-Panel View mode, follow the steps below:
Step Action
1 Enter
User Code (for users 001-050)
+
[#]
+
[87].
The keypad displays the following typical display:
ALLPANEL 1 2 3 4 5 6 7 8
STATUS x x x x x x x x
where 12345678 are the panel ID numbers and xxxxxxxx is the overall status of each panel. Status
indications include:
A
= Armed Away
S
= Armed Stay
M
= Armed Maximum
I
= Armed Instant
R
= Ready
N
= Not Ready
B
= Bypassed/Ready = Alarm
T
= Trouble
F
= Fire Alarm
P
= AC Power Failure
L
= Low System Battery
C
= Comm Fail
NOTE:
See table later in this section for priority of displays.
2 The following functions can be performed::
Press
[1]
to attempt to disarm all partitions on all panels.
Press
[2]
to attempt to arm AWAY all partitions on all panels.
Press
[3]
to attempt to arm STAY all partitions on all panels.
Press
[4]
to attempt to arm MAXIMUM all partitions.
Press
[7]
to attempt to arm INSTANT all partitions.
Press
[0]
to exit mode. After a few seconds, the keypad displays the status of the original partition of the
original panel for the keypad. Also, this mode will end in approximately 120 seconds if no keys are pressed.
NOTES:
When performing any of the arming commands, if there are faults in any of the partitions of a panel, the
system will not arm that panel, but will arm all the other partitions of the other panels.
When performing either a STAY or INSTANT arm command, the system always arms in mode 1 (see the
VISTA-128BP/VISTA-250BP User Guide
for a detailed explanation of the STAY and INSTANT arming
modes).
The user cannot execute another panel linking mode. In order to perform another panel linking mode or to
access a different remote panel, the user must first exit this mode (return to the original control panel).
Priority of Displays for Multi-Partition and Multi-Panel Modes
This table shows the priority of displays if more than one of these conditions exists at the same time.
Priority Description Display Priority Description Display
1 Fire Alarm
F
8 Not Ready
N
2 All Other Alarms
9 Ready
R
3 AC Loss
P
10 Armed STAY
S
4 Comm Fail
C
11 Armed AWAY
A
5 System Low Battery
L
12 Armed INSTANT
I
6 Trouble
T
13 Armed MAXIMUM
M
7 Bypass
B